background image

3

Watts TD-300 installs during new construction or in existing floors
 

Elevator/Threshold channels should sit slightly below flooring to ensure a smooth    

  transition from one area to another when the grate is installed. The grate should 
  match up flush with the floors and create a safe level transition.

Installing the channel
 

Leader drain pipes must be installed to connect with the center or end drain outlet  

  in order to divert and filter excess water.

 

Leader drain pipes are used to connect the drain to the intended drain lines. These  

  pipes should be in place and designed to connect to the drain outlet whether it is   
  located in the center or in the ends of the channel.

 

The drain is designed to fit into "boxed-out" areas in both new construction and in  

  existing floors.
  Wood is used to create a form or boxed-out area to hold the channel. 

 

Create a solid level base for the channel. This may be done with concrete or other  

  materials. Use a level to ensure that the channel is level and will properly meet 
  floor level when grate is installed.
  Form the approach to the entrance by laying the required sub-base up to the
  channel, leaving sufficient space for the surface finish. Any final adjustments
  should be made at this time.
  Anchor straps may be screwed into existing concrete or flooring, or screwed into   
  wood forms to hold the channel steady during a concrete pour.
  Concrete may be poured around the channel.

Anchor Strap

Top View

Summary of Contents for TD-300

Page 1: ...nd indoor areas Available in lengths from 36 min to 96 max 12 ga 304 stainless steel is engineered for both durability and style Removable grating allows for low maintenance and easy installation TD 3...

Page 2: ...ndard with center outlet End outlets are available by special request Please make sure that you have specified the correct area before installation begins Note Minimum dimensional requirements must be...

Page 3: ...it is located in the center or in the ends of the channel The drain is designed to fit into boxed out areas in both new construction and in existing floors Wood is used to create a form or boxed out a...

Page 4: ...ine your rights SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR...

Page 5: ...int rieures Offert en longueurs de 36 po min 96 po max 914 mm min 2 438 mm max L acier inoxydable 304 de calibre 12 est sp cialement con u pour la durabilit et le style Le retrait des grilles permet...

Page 6: ...ties d extr mit sont disponibles par demande sp ciale Assurez vous d avoir pr cis la zone appropri e avant de pr parer l installation Remarque les exigences minimales de dimensions doivent tre respect...

Page 7: ...ou l extr mit de la canalisation Le drain est con u pour tre log dans des zones encastr es dans les constructions neuves et les planchers existants Le bois est utilis pour cr er une forme ou une zone...

Page 8: ...naissance des lois applicables pour votre cas particulier LA DUR E DE TOUTE GARANTIE IMPLICITE PR VUE PAR LA LOI EN APPLICATION ET DEVANT DONC TRE ASSUM E Y COMPRIS LES GARANTIES IMPLICITES DE QUALIT...

Reviews: