11
EN
Temperature
LED color
T ≤ 18°C
blue
18°C < T ≤ 20°C
azure
20°C < T ≤ 22°C
green
22°C < T ≤ 24°C
orange
T ≥ 24°C
red
6.2 Opened windows detection
Enter user parameter 06.
When activated and a detection is run-
ning, the icon
will appear and blink
on the screen!; This function is done by
measuring and recording the temperature
evolution.
When an opened window is detected, the
thermostat applies to heating system anti-
freeze temperature set point. User can
restart heating system, and stops window
detection by pressing on a key.
6.3 Keyboard locking
Wake-up the thermostat (lighted back-
light),
Press and hold
and
keys
simultaneously.
Once locking is activated, logo
appears on the LCD screen:
6.4 PIN code
To activate this function enter user param-
eter 9.
The PIN code protect the thermostat from
any change of the setting as temperature
or mode.
When user pushes a key, “PIN” will be dis-
played. If user press another time a touch,
he has to enter PIN number.
6.5 Heating and cooling indications
Logos used to indicate than system
requires:
heating is
; cooling is
.
6.6 LED indication
When user modify set point temperature in
functioning mode, behavior information is
displayed with a LED RGB located on the
middle of validation key.