background image

13

Performance Data Sheet

Watts  •  815 Chestnut Street  • N. Andover, MA 01845  •  Phone: 800-659-8400

Model: *WQC4RO11, WQC4RO11-50MTNF, WQC4RO11-50PTNF, 

*WQC4RO13-100, WQC4RO13-100MT, and WQC4RO13-100PT

*(WQC4RO11 and WQC4RO13 models not certified .)

GENERAL USE CONDITIONS:

1 .  Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system . 

Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts . 

2 .  Operating Temperature:

Maximum  100° F (38° C)

Minimum 40° F (4 .4° C)

3 .  Operating Water Pressure:

Maximum  85 psi (5 .98 kg/cm²)

Minimum 20 psi (1 .41 kg/cm²)

3 . Maximum flow Rate:

0 .50 gpm (1 .89 lpm)

     

  

 

RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:

Note: Depending on incoming feed water conditions replacement time frame may vary .

Determine if you have an 11 inch or 13 inch product.

Model # 

Part # 

Description

Replacement Interval

WQCSC11

68108818

Stage 1:       Sediment Filter (11 inch)

6 months

WQCSC13

68108819

Stage 1:       Sediment Filter (13 inch)

6 months

WQCCC11

68108777

Stage 2:       Pre-Carbon Filter (11 inch)

6 months

WQCCC13

68108779

Stage 2:       Pre-Carbon Filter (13 inch)

6 months

WQCM11-50

68108809

Stage 3:       RO Membrane Filter (11 inch-50 GPD)

2-5 Years

WQCM13-100

68108810

Stage 3:       RO Membrane Filter (13 inch-100 GPD)

2-5 Years

WQCGAC11

68108795

Stage 4:       Post Carbon Filter (11 inch)

12 months

WQCGAC13

68108796

Stage 4:       Post Carbon Filter (13 inch)

12 months

System tested and certified by WQA against NSF/ 

ANSI Standard 58 for the reduction of the claims 

specified on the performance data sheet and NSF/ 

ANSI Standard 372 for lead free .

Summary of Contents for WQC4RO11-50

Page 1: ...t Technical Warranty Information Performance Data Sheet 13 14 Arsenic Fact Sheet 14 Service Record 15 Limited Warranty 16 System tested and certified by WQA against NSF ANSI Standard 58 for the reduct...

Page 2: ...s The second stage contains a five micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane Recommended change...

Page 3: ...local regulations during installation Contents of Reverse Osmosis RO System 1 Tank 1 RO Module with Filters 1 Parts Bag 1 Faucet Box 1 Manual If any of the items are missing please contact prior to i...

Page 4: ...01504 Automatic Shut Off Valve ASOV J FU AGLR C 3 68102443 Air Gap Long Reach Chrome Faucet Option K FNP3033CP US05 68102285 Non Air Gap Long Reach Chrome Faucet Option L F122051 68101496 50 GPD Flow...

Page 5: ...g it for a sprayer or soap dispenser see Step A NOTICE Porcelain sinks are extremely hard and can crack or chip easily Use extreme caution when drilling Watts accepts no responsi bility for damage res...

Page 6: ...l screwdriver to feed through the drain saddle into the drain pipe to aid with the alignment Using a Phillips screw driver tighten the drain saddle bolts evenly and securely on both sides NOTICE Do no...

Page 7: ...cat ed at the bottom of the recess for the tank connection Step 2 B Thread the plastic valve onto the tank fitting NOTICE DO NOT use teflon tape on plastic tank DO NOT over tighten or the valve could...

Page 8: ...you have an 11 inch or 13 inch product and replace in 12 mos Model Part Description WQCSC11 68108818 Sediment Filter 11 inch WQCSC13 68108819 Sediment Filter 13 inch WQCCC11 68108777 Pre Carbon Filter...

Page 9: ...nce complete DANGER IF BLEACH GETS IN EYES Hold eye open and rinse slowly and gently with water for 15 20 minutes Remove contact lenses if present after the first 5 minutes then continue rinsing eye C...

Page 10: ...frequently over the next 24 hours to ensure no leaks are present NOTICE If you have connected your RO system to a refrigerator ice maker make sure the ice maker is off do not allow water to flow to t...

Page 11: ...ntinues check incoming water 3 System is constantly running Crimps in tubing Check tubing and straighten or replace as necessary Clogged pre filters Replace prefilters Fouled Membrane Replace Membrane...

Page 12: ...taste from water Tank needs to be sanitized Sanitize your system Filters are Fouled Replace Filters Filters weren t removed prior to an ex tended period of non use Replace filters and Sanitize your s...

Page 13: ...MENT PARTS AND CHANGE INTERVAL Note Depending on incoming feed water conditions replacement time frame may vary Determine if you have an 11 inch or 13 inch product Model Part Description Replacement I...

Page 14: ...Sheet Performance Data Sheet cont This system has been tested according to NSF ANSI 58 for reduction of the substances listed below and to NSF ANSI 372 for lead free com pliance The concentration of...

Page 15: ...__________ Model Number WQCRO4 Serial Number ______________ Date of Install _________________ Installed by __________________ Date Changed Sediment Pre Filter 6 Months Carbon Pre Filter 6 Months Membr...

Page 16: ...d 100 pounds per square inch 6 Incoming water to the filter system cannot exceed 100 degrees F 38 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is...

Reviews: