background image

4

2  Packing List

R F I D  

CARD

Charging 

Station (with 

Connector)

Connector 

Holster

Wall Anchor
(7 pcs)

Type C Screw 
(M4 x 30 mm)

(7 pcs)

Type B Screw

(M4 x 10 mm)
(4 pcs)

Screw Terminal 
Strip

Wall-dock 
Back Panel

RFID Card

(2 pcs)

Product Quick 
Guide

Type A Screw 

(M4 x 12 mm)
(4 pcs)

User Manual

Summary of Contents for US12

Page 1: ...Congratulation on your new EV charger Read this manual carefully before use and keep it for future reference 12kW AC EV Charger User Manual Model US12 ...

Page 2: ...roduct Overview 5 4 Installation 6 4 1 Charging Station Installation 6 4 2 Connector Holster Installation 9 5 Charging Operation 10 5 1 Plug and Charge Mode Default 10 5 2 RFID Mode 10 6 LED Indicator 12 7 Troubleshooting 12 8 Safety Warning 14 9 Warranty 15 ...

Page 3: ... Protection Leakage Current and Ground Fault Protection Lightning Protection Overvoltage Protection Undervoltage Protection Overcurrent Protection Overtemperature Protection Ground Fault Detection CCID 20 Warranty 2 years Standards UL2594 UL2231 1 2 Status Display LED Charging Cable Length 24 6 ft 7 5m Input Wiring Hardwired Input Cord L1 L2 PE AC Power Input Rating 240 15 Va c 50 60 Hz 50A Max AC...

Page 4: ... Station with Connector Connector Holster Wall Anchor 7 pcs Type C Screw M4 x 30 mm 7 pcs Type B Screw M4 x 10 mm 4 pcs Screw Terminal Strip Wall dock Back Panel RFID Card 2 pcs Product Quick Guide Type A Screw M4 x 12 mm 4 pcs User Manual ...

Page 5: ...5 3 Product Overview Led Indicator RESET BUTTON Input Cable Entry Connector Holster RFID Reader Interrogator Screw Terminal Strip Wall dock Back Panel Connector Plug ...

Page 6: ...ten the screw terminal strip into the wall dock back panel using 4 type B M4 x 10 mm screws 4 1 2 Find the wall stud nearest to the power supply wiring place the wall dock back panel to the wall stud and mark 4 mounting holes M4 then remove the back panel wall M4 M4 M4 M4 ...

Page 7: ...7 4 1 3 Drill 4 holes M4 and insert 4 wall anchors into the mounting holes 4 1 4 Place the back panel then screw and tighten 4 Type C M4 x 30 mm screws into the mounting holes ...

Page 8: ...dwired 4 1 6 Align the charging station with the wall dock back panel gently insert and assemble The input cables pass through the waterproof holes Connect the wires L1 L2 PE per the diagram and tighten each screw ...

Page 9: ...all and keep it level and mark the 3 mounting holes M4 then remove the holster wall dock 4 1 7 Screw and tighten the charging station into the wall dock back panel using 4 Type A M4 x 12 mm screws wall 4 2 Connector Holster Installation M4 M4 M4 ...

Page 10: ...rging station is on standby plug in the connector to your EV and the LED will turn blue from purple The LED will be flashing green while charging When your EV is fully charged the LED will be solid green unplug the connector and place it back into the holster 5 Charging Operation 5 1 Plug and Charge Mode Default 5 2 RFID Mode If you need an emergency stop while charging please press the RESET BUTT...

Page 11: ...ration 2 Once you enable the RFID mode the plug and charge mode will be disabled if you want to use the plug and charge mode please contact us for tech support When the charging station is on standby plug in the connector to your EV and the LED will turn blue from purple Tap the RFID card on the RFID Reader The LED will be flashing green while charging Tap the RFID card on the RFID Reader again to...

Page 12: ...ower on the device again If the fault persists contact us The red light flashes slowly twice and quickly twice alternately cycle Output Overcur rent 1 Immediately turn off the leakage over current protection switches in the power distribution box 2 Check whether there is low imped ance or short circuit between the char ger output line 3 Ensure the charging current to less than 35A 4 After the faul...

Page 13: ... the leakage over current protection switches in the power distribution box 2 Check whether the charger output line is damaged or has low impedance to the ground or short circuit 3 After the fault is rectified power on the device again If the fault persists contact us The red light flashes slowly for 3 times and quickly once alternately cycle L PE Connected Reversely 1 Immediately turn off the lea...

Page 14: ...le materials chemicals or vapors Please do not use the product if the enclosure or the EV connector is frayed broken otherwise damaged or fails to operate Please do not operate this product at a temperature beyond 30 to 55 C Please do not repair or refit without authorization contact our support for help Please do not disassemble safety signs warning notices labels or markings Please do not spray ...

Page 15: ...ll either 1 replace the product or 2 exchange the product with a product that is of equal value A replacement product assumes the remaining warranty of the original product or 180 days from the date of replacement whichever is greater Customers are responsible for the return shipping costs Wattsaving s warranty policy does not apply to 1 Products purchased from unauthorized resellers 2 Products ha...

Page 16: ...support wattsaving com www wattsaving com SHENZHEN WATTSAVING ELECTRICAL TECHNOLOGY CO LTD Made in China ...

Reviews: