7.22.
SMONTAGGIO BATTERIA
Figure 7.22-1
Carry out the operations described in paragraph
7.7. “Disassembling the guards”.
1.
Remove the 2 cable ties
(a)
.
2.
Unplug the 2 fastons
(b)
and remove the
battery, replace if is necessary.
To reassemble the battery carry out the above
steps in reverse order.