CARDIO WAVE EXCITE Class & Trend: Service & maintenance manual- rev.2.0
Page 12.1
12.
APPENDIX
12.1.
UPDATING THE SW
To update the machine SW it is necessary to change the contents of the FLASH EPROM on the 386
or ARM board by means of an external PC connected to the CSAFE port on the machine, situated
on the lower part of the display panel.
The PC can only update the FLASH EPROM during machine power up, before the self-
test sequence begins.
After the Display SW update it is necessary to restore all the parameters to the default
values following the detailed instructions provided in paragraph: 9.2.13. “Resetting
parameters to default values”.
After the lower electronic SW update it is necessary to restore all the parameters to the
default values following the detailed instructions provided in paragraph: 9.5.1.3
“Default Setting”.