background image

FLO19.rev00 

 

Contents Flostream Installation and Cartridge 
Replacement Instructions

 

Section    

 

 

 

 

 

 

 

         

Page

 

1.         Introduction 

 

 

 

 

 

 

 

1.1 

Important   

 

 

 

 

 

 

 

1.2 

What it does 

 

 

 

 

 

 

 

1.3 

Before you begin   

 

 

 

 

 

 

2. 

Tools and Fasteners 

 

 

 

 

 

 

3

 

3. 

Basic Components                              

 

 

 

 

4. 

Flostream Filter System Specifications 

 

 

 

 

5. 

Fitting Flostream (flexi hose installation)   

                

 

6. 

Cartridge Replacement   

 

 

 

 

 

7.

 

Functional Checks  

 

   

 

 

 

 

 

5

 

7.1 

Installation check   

 

 

 

 

 

 

5

 

7.2 

Operational / Maintenance check 

 

 

 

 

 

8.

 

Approvals 

           

 

 

 

 

 

 

 

 

 

 

 

 

Section 1

.

 

Introduction 

 

1.1 Important  

It is important to us that this product works as advertised and that you enjoy the extra peace of 
mind that Flostream offers. If you have any queries that can not be answered by your supplier 
or engineer, please contact us direct on +44 (0) 1476 861717 or e-mail 

info@waveinternational.co.uk

 

 

1.2 What it does

 

 

The Flostream drinking water filter systems produce premium quality, healthy water at point of 
use, in cabins and galleys, for all food service applications. 

 

Importantly Flostream eliminates the need for disposable water bottles onboard. 
 

o

 

Removes Chlorine, improving taste and odour.  

o

 

Cyst reduction, removes contaminants that cause health issues. 

o

 

Lime-scale and KDF inhibition (Flostream), KDF successfully extends filter life and 
increases the performance of the media and helps maintain its efficiency.  

o

 

Bacteriostatic control to inhibit microbial growth in the water system. 

o

 

Cartridge easy connect/release with a quarter turn, replace after 6 months or sooner if 
required. 

o

 

Install in vertical position with cartridge hanging below for easy replacement. 

o

 

Simple installation with push fit connections for standard 10mm flexi pipe, other 
optional size connections available  

o

 

Recommended flow rate 1.90 L/min.. 

o

 

Pressure range  0.7 - 8.5 bar. / Temperature range 2 - 38 degress centigrade. 
 

Reviews: