11
Solid ORANGE
(Battery inserted.)
Indicates (A) battery is too cold or (B) charger is performing a
temperature diagnostic when the battery is inserted. If (A), the battery
temperature is 0°C (32° F) or below and charging is delayed for up to
two hours. Battery is monitored and charging resumes once it is above
freezing. Monitoring terminates if the battery temperature remains
below freezing for two hours. Remove battery and reinsert once battery
reaches room temperature. If (B), battery type requires additional time
to determine its temperature. This is generally completed within a few
minutes after insertion.
Flashes ORANGE
1 Time
Battery temperature remains at 0°C (32° F) or below after two hours of
monitoring. Remove battery from charger and allow it to warm.
Flashes ORANGE
2 Times
Indicates charging complete, but battery is under charged. Battery
voltage is below minimum level required. This warning is provided
after the rapid charging stage is complete.
Fault Conditions & Advisements
(continued)
LED Pattern
Advisement