background image

 

 

12 

 

DISPLAY BACKLIGHT 

Press the

 

 key  to turn the backlight on. The backlight will automatically  turn off after 

SET time.

 Press the 

EXIT

 button  to exit  the 

backlight on

 mode. 

 

HOLD 

The  hold  function  freezes  the  reading in the display.  Press the

  HOLD

 key momentarily  to 

activate  or to exit the

  HOLD

 function. 

 

PEAK HOLD 

The  Peak Hold function  captures  the peak AC or DC voltage  or current.  The  meter can  capture 
negative  or positive peaks as fast as 1 millisecond in duration.  Momentarily  press the 

PEAK

 

button,  “

PEAK

” and “

MAX

” will display in 

left auxiliary  display

MIN

” will display in 

right 

auxiliary display

. The  meter  will  update the  dispay each  time a lower negative  peak occurs

Press the 

EXIT

  button to exit the 

PEAK HOLD

 mode.

 Auto  Power Off feature  will be disabled 

automatically  in this mode. 

 

Data record

STORE/RECALL

 

 

 

1.  STORE function   

In  the  current  testing mode, press STORE button  one time, enter  into  STORE function. 

 

On  the  left upper corner  of LCD shows NO  XXXX

.

which  states current  storage serial number.  Then,  press button  PEAKHOLD to change  into  the
 initial serial number  0000. (Press again it will  change  back).   

 

On  the  right upper corner  of LCD shows XXXX 

which  states how  many  current  storage 

values  are used.   

 

Press STORE  button  again, enter  into recording interval  time set up function.    

 

On  the  left upper shows  0000 S 

which  states recording interval  time; using  button  + & -

 to select

the  range is 0~255 seconds

 

 

When  the  recording interval  time is 0000 S

then  press STORE button  again to change  into 

manual  recording.  Press the  STORE button  again to record once. 

 

When  the  recording interval  time is 1~255 S

then  press STORE button  again to start recording 
automatically  from 0000.  
Recording times is showed  on the  left upper  corner,  data is showed  on the  right  upper corner 
(Due to digital limitation,  there  is only  four  preceding numbers  displayed) 

 

To finish  above STORE  function,  press EXIT  button  shortly. 

 

If  you  expect to clear all  memory  data:  
While power on, hold EXIT button, and switch from OFF to random and then release EXIT butt
on,  the LCD will  flash  thrice and  buzzer  thrice  too, which  means  all memory  data is cleared. 

 
 
 
 
 

Summary of Contents for 98

Page 1: ...True RMS Industrial Multimeter MODEL WAVECOM 98 10A mA A Wavecom Instruments Pty Ltd 257 Grange Road FINDON SA 5023 P 61 08 8243 3500 F 61 08 8243 3501 sales wavecom com au www wavecom com au...

Page 2: ...2...

Page 3: ...minals identifies them as being associated with ranges that may in normal use be subjected to particularly hazardous voltages For maximum safety the meter and its test leads should not be handled when...

Page 4: ...n nano 10 9 capacitance micro 10 6 amps cap m milli 10 3 volts amps A Amps k kilo 103 ohms F Farads capacitance M mega 106 ohms Ohms PEAK Peak Hold Hz Hertz frequency V Volts Percent duty ratio REL R...

Page 5: ...na plug into the negative COM jack Insert the red test lead banana plug into the positive V jack 3 Touch the black test probe tip to the negative side of the circuit Touch the red test probe tip to th...

Page 6: ...e main display 7 Press the MODE button again to indicate 8 Read the of duty cycle in the main display 9 Press EXIT for 2 seconds into the function of AC DC Test DC and AC TRUE Rms mV VOLTAGE MEASUREME...

Page 7: ...nger than 30 seconds Exceeding 30 seconds may cause damage to the meter and or the test leads 1 Insert the black test lead banana plug into the negative COM jack 2 For current measurements up to 4000...

Page 8: ...is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading 5 Read the resistance in the display CONTINUITY CHECK WARNING To avoid e...

Page 9: ...icate near 0V and an open device will indicate OL in both polarities CAPACITANCE MEASUREMENTS WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors befor...

Page 10: ...s 5 Read the temperature in the display Note The temperature probe is fitted with a type K mini connector A mini connector to banana connector adaptor is supplied for connection to the input banana ja...

Page 11: ...de The display icon MAX will appear The meter left auxiliary display will display and hold the maximum reading and will update only when a new max occurs The display icon MIN will appear The right aux...

Page 12: ...XX which states current storage serial number Then press button PEAKHOLD to change into the initial serial number 0000 Press again it will change back On the right upper corner of LCD shows XXXX which...

Page 13: ...entation and choose the appropriat e driver for your PC Operating System 3 Connect the USB Wireless Receiver to your PC 4 Double click the multimeter icon or access from the Start menu on your PC and...

Page 14: ...parameter 2 Press SET button continuously to switch to setting content till exiting set up to testing mode So the updated setting content is saved If press EXIT button in this period all setting can...

Page 15: ...chemicals cleaning solvents or detergents 5 USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE Remove old or weak batteries so they do not leak and damage the unit 6 IF THE METER IS TO BE STOR...

Page 16: ...the battery 4 Remove the six A screws securing the rear cover 5 Gently remove the old fuse and install the new fuse into the holder 6 Always use a fuse of the proper size and value 0 5A 1000V fast bl...

Page 17: ...ent 400 A 0 01 A 1 0 reading 3 digits 4000 A 0 1 A 40mA 0 001mA 400mA 0 01mA 10A 0 001A 20A 30 sec max with reduced accuracy AC Current AC DC 50 to 1000Hz 400 A 0 01 A 1 5 reading 30digits 4000 A 0 1...

Page 18: ...40MHz 0 001MHz 100MHz 0 01MHz Not specified Sensitivity 0 8V rms min 20 to 80 duty cycle and 100kHz 5Vrms min 20 to 80 duty cycle and 100kHz Frequency electrical 40 00HZ 10KHz 0 01HZ 0 001KHz 0 5 rea...

Page 19: ...r range indication OL is displayed Auto Power Off 15 minutes approximately with disable feature Polarity Automatic no indication for positive Minus sign for negative Measurement Rate 2 times per secon...

Page 20: ...Road FINDON SA 5023 Ph 61 08 8243 3500 Fax 61 08 8243 3501 Email sales wavecom com au Web www wavecom com au Melbourne 772A Station Street BOX HILL VIC 3128 Ph 61 03 9897 4711 Fax 61 03 9897 4766 Ema...

Reviews: