  Abnormal Compressor ‘ Warning’   

During  operation,  any  malfunction  can  trip  the  compressor  to  fail,  resulting  in  a  compressor  shut  off.  It 

takes 3 minutes to recover from the protection period. 

 

 

After  the  water  reservoir  is  removed  it  takes  about  3  minutes  to  start  up  the  unit  again  for 

protection  purposes.  To  avoid  this  protection  period,  simply  remove  the  plug  from  power 

socket to restart the unit. 

 

  Protection Of Extremely Low & High Temperature 

1. When the sensor on the air intake detects ambient temperature 

0ºC or 

40ºC, the appliance will shut off 

automatically for protection, and the warning beeps will continue with 3 long and 2 short signals. 

When the sensor detects ambient temperatures 

0ºC, 0ºC is showed on the LCD display. 

When the sensor detects ambient temperatures 

40ºC, 40ºC is showed on the LCD display. 

  2. When sensor on the evaporator detects its temperature 

40ºC, the appliance will shut off automatically 

for protection, and the symbol for automatic defrost            illuminates.     

 

1. If all function keys are not working, you should switch off at the mains to restart the unit. 
2. After the unit has experienced extremely low & high temperature, the appliance will not 
keep its memory function when restart. 

 

  Failures Of Humidity & Temperature Sensor 

1. When  an  error  between  the  humidity  and  temperature  sensor  occurs,  the  symbol  of  dehumidification       

will flash, and “0ºC” “0%RH” is displayed on the LCD display. At this point the appliance adopts the 

continuous dehumidifying mode. 

 

1

  If  the  temperature  sensor  malfunctions,  the  appliance  will  adopt  the  continuous 

dehumidification mode and not a controlled humidity setting.   

2

  This malfunction will not influence the dehumidification. 

 

2. When the temperature sensor of the evaporator is an open circuit or short circuit, the symbol of defrost       

 

    will  flash,  and  the  appliance  turns  to  dehumidifying  and  defrosting  mode:  dehumidifying  for  20 

minutes, then defrosting for 5 minutes.       

 

1

If the temperature sensor malfunctions, the keys within the control panel will perform normally. 

2

If the temperature sensor malfunctions, the appliance will continue to work with lower efficiency.   

 

  Memory Function 

If  the  power  supply  is  cut  off  when  the  appliance  is  running,  it  will  memorise  its  working  mode 

automatically. Once power has been restored, the appliance will restart and continue in this working 

mode.         

       

 

Summary of Contents for WL-YL-2612B

Page 1: ...User s Manual Model No WL YL 2612B...

Page 2: ...unctions of Control Panel Key Pads LCD Display Operation of Key Pads Automatic Defrosting Water Tank Full Warning Processions Of Abnormal Compressor Protection Of Extremely Low High Temperature Failur...

Page 3: ...re the inlet and outlet ventilation is not blocked at any time 2 To avoid an electric shock avoid placing the unit near window or in a bathroom 4 Do not operate this unit in an explosive or corrosive...

Page 4: ...6 Unplug the appliance during cleaning Ambient Environment For Operating 1 Working environment Lowest ambient temperature 5 C 40 RH Highest ambient temperature 35 C 90 RH 2 Always operate the unit ind...

Page 5: ...Component Diagrams Air deflector Control panel...

Page 6: ...tch the power button on the unit to start up 2 Press mode to select the desired working mode and the corresponding indicator light will illuminate 3 Press Setting to select the desired running mode an...

Page 7: ...fying mode will be cancelled 2 Press Mode or three seconds after pressing Setting the desired humidity ratio is set and the indicator light switches off 3 When sensor detected ambient humidity is 1 lo...

Page 8: ...r To ensure the unit performs well in these conditions an automatic defrost function is fitted to the appliance 1 When a room temperature drops down to 16 or less the compressor works for 25 minutes d...

Page 9: ...start the unit 2 After the unit has experienced extremely low high temperature the appliance will not keep its memory function when restart Failures Of Humidity Temperature Sensor 1 When an error betw...

Page 10: ...he last set mode 2 If the power supply is shut off into a protection mode the appliance will not recover back to the last set mode Continuous Drainage Remove water plug and connect with PVC hose with...

Page 11: ...rection as shown on figures Use a vacuum cleaner or water to clean and then put it in ventilated place until it s dry Always switch off and unplug before moving this unit When packing away this unit f...

Page 12: ...d 220 240VAC 50Hz Moisture removal 12 L D 30 RH80 Dehumidifying Power 255W 30 RH80 Max Power Dissipation 300W 35 RH90 Dehumidifying Air Volume L 80m3 h H 100 m3 h Refrigerant R134a 120g Capacity of Wa...

Reviews: