28 / 69
CPDE 39
ON/OFF
START/STOP CHARACTER
"The Start/Stop character is located at the front and end of the barcode. The Start/Stop character
can be configured to be transmitted or not transmitted. The default is no transmission.
CHECK CHARACTER
No check character means that the device will read and transmit all barcodes whether there is a
check character or not. (At this time, when scanning the barcode with check characters, the check
characters are transmitted together.)
When "Check Character" is set to "Enable Without Check Character Transmission", the device will
check according to the last digit data of the barcode. If the check passes, normal data except the
last check character will be transmitted. If the check fails, the barcode content will not be sent.
Default Code 39
Configuration
*On
Off
Transmit
* Not Transmit