background image

5 of 9

WX-501-0536 • 01.22

6.  Press the push-button again to select the function. Once selected, the function will either start running or the 

second submenu (red LEDs) will start (the first LED will light up).

7.  Hold the push-button to cycle through the second submenu. 
8.  Release the push-button once the desired submenu selection is displayed. 
9.  Press the push-button again to select the function. The function will now start running.

Sensor Emulation

Sensor Emulation is the first mode presented in the menu selection process (blue flashing). It is also the default 

mode and will be running the first time the device is powered on. (After you have switched to another operating 

mode, the device will return to that mode after a power cycle.)

Sensor Emulation mode is used for testing connections between a sensor and other devices. The Click 510 can 

mimic a SmartSensor 105 and send traffic data, allowing you to see if breaks in communication are caused by the 

communication channel or by the sensor itself. It also allows you to check the functionality of an assembled traffic 

cabinet before attaching a sensor. In both these cases, the response can be monitored with a contact closure 

module such as the Click 100, 172, or 174.

This mode has two submenus on which you can specify the traffic data and how it will be sent.

1st LED

2nd LED

3rd LED

4th LED

Submenu 1 (Yellow LEDs)

1 second

0.25 – 1 second

Switch

-

Submenu 2 (Red LEDs)

17’/60’  30 – 60 mph Random Traffic

Diagnostic Traffic

-

Sensor Emulation submenu 1 allows you to select when the Click 510 sends out data packets. Submenu 1 

selections are displayed on the device as the yellow LEDs (see the table above). 

 

1 second –

 Sends data every second.

 

0.25 to 1 second –

 Sends data every 0.25 to 1 second.

 

Switch –

 Sends data every time the push-button is pressed.

Note. 

If you would like to have the Click 510 emulate a sensor, but not actively transmit any data, use submenu 1 

to select the Switch option. As long as you don’t press the push button the sensor will be passive. This will allow 

you to use the Click 510 in conjunction with a Click 100, 172, or 174. Once the Click 510 is passively emulating 

a sensor, you can configure the connected contact closure device. After configuration, you can then press the 

push-button to send traffic data, or you can select a mode that pushes data automatically.

Sensor Emulation submenu 2 allows you to select which traffic data packet will be sent to the computer. Submenu 2 

selections for Sensor Emulation mode are represented on the device as the red row of LEDs (see the table above).

 

17’/60’ 30–60 mph

 – Sends a traffic data packet containing 17- and 60-foot vehicles going speeds of 30–60 

mph. The first four packets show a 17-foot vehicle going 30 to 60 mph in increments of 10 mph. The next four 

will be a 60-foot vehicle going 30 to 60 mph in increments of 10 mph. This sequence of eight packets starts on 

lane 1 and ends on lane 8 (e.g. lane 1 detections are always 17 feet long at 30 mph.) You can monitor these simu-

lated detections with a contact closure module; additionally, if you are connected via HyperTerminal, you will see 

strings of text appear (see the figure below).

 

Random traffic –

 Sends random combinations of lane, duration and speed across your communication channel. 

Use this setting as a basic test of your communication channel. You can monitor these simulated detections with 

a contact closure module; additionally, if you are connected via HyperTerminal, you will see strings of text appear.

 

Diagnostic traffic –

 Sends a wide array of data combinations (mixture of lane, duration, and speed values) across 

Summary of Contents for 0536

Page 1: ...e features of v2 0 operate differently than that of the v1 0 product which had a custom platform The following documentation is specific to v2 0 If you have an earlier version of the Click 510 you will need to refer to previous documentation Contact Wavetronix Support for assistance Physical Features The Click 510 physical features are used for easy installation and configuration T Bus Connector R...

Page 2: ...ther Click modules While it can be used to convert RS 485 communications to RS 232 this is not its normal usage Instead on the Click 510 this port is normally used to upgrade the Click 510 program or reprogram the unit for custom applications However if you are using a modified RS 232 DB 9 serial cable connector with the DTR pin removed it can be used to convert RS 485 communications to RS 232 Not...

Page 3: ...e Click 510 is installed on a T bus with active power and RS 485 If you are going to use your Click 510 in conjunction with a computer serial port and terminal program make sure there is a serial connection between the computer and the Click 510 or between the computer and another device on the same T bus as the Click 510 Remember that if you want to use the RS 232 DB 9 port on the front of the mo...

Page 4: ...en Flashing Green On with Red Flashing Autobaud Green Solid Green Solid Latency Test Yellow Solid Yellow Solid Reset Red Flashing Red Flashing Note The LED state during the mode selection process can be either flashing or solid If the current mode is a flashing mode the corresponding blue or green LED will flash during mode selection see column 2 of the table above However once a flashing mode is ...

Page 5: ... 1 second Sends data every 0 25 to 1 second Switch Sends data every time the push button is pressed Note If you would like to have the Click 510 emulate a sensor but not actively transmit any data use submenu 1 to select the Switch option As long as you don t press the push button the sensor will be passive This will allow you to use the Click 510 in conjunction with a Click 100 172 or 174 Once th...

Page 6: ...will be sent 1st LED 2nd LED 3rd LED 4th LED Submenu 1 Yellow LEDs 1 second 0 25 1 second Switch Submenu 2 Red LEDs LED flash LED sequence ASCII sequence ASCII text Test Pattern submenu 1 allows you to select when the Click 510 sends out data packets Submenu 1 selections are displayed on the device as the row of yellow LEDs see the table above 0 25 to 1 second Sends data every 0 25 to 1 second 1 s...

Page 7: ...yperTerminal 1 8 Lights up the corresponding LED on the Click 510 For example typing a 5 causes the fifth LED to illu minate The yellow LEDs are numbers 1 4 and the red LEDs are numbers 5 8 f Causes all the submenu LEDs to flash at once this is the same as LED flash on the 510 menu s Causes each submenu LED to flash in sequence this is the same as LED sequence on the 510 menu The sequence will beg...

Page 8: ...ate has been set to match the sensor The discovery process attempts all the baud rates listed in the figure above SmartSensor V autobaud discovery requests are sent at each baud rate If a response to a request is received the Click 510 baud rate will be set to match the SmartSensor baud rate Each baud rate is attempted 10 times with a longer wait time on each successive iteration During the discov...

Page 9: ...r to the tables that come up in HyperTerminal as shown in the figure below If you are not connected to the computer and want a general idea of the delay time you can refer to the submenu LEDs on the device The device will show results for each packet size starting with the 16 byte size shown by the first yellow LED When each yellow LED illuminates the corresponding delay time information will be s...