Note.
These parameters can also be configured using the DIP switches or the front panel menu; if in the DIP
switches they are set to Hardware mode, the parameters will appear grayed out on this screen. The exception is the
Fault Detect Time; this is the only place it can be set.
Setting
Description
Fault Detect Time
Lets you set the amount of time that a bus can go without receiving data before going into a fault
state.
Master Fault Polarity
Lets you choose the polarity of the master fault output (whether the voltage is low or high when
the output is asserted).
Chan. Out Polarity
Lets you choose the polarity of the output channels (whether the voltage is low or high when
there is a call on that channel).
Fault Enable
Lets you enable or disable the card’s fault state. If it’s disabled, the Click 111 will never go into a
fault state.
Fault State
Lets you select what happens when the Click 111 is in a fault state (whether that triggers a call or
not).
Under the
Diagnostics
tab, you can run diagnostics on your device (see the figure below).
Click the
General
button to run diagnostics on the items listed below the button. If a problem is detected, the
program will display a red square next to the item in question. If no problems are detected, a green circle will
appear.