12 of 15
WX-501-0518 • 01.22
See the earlier Navigating through the Menu and the Menu Operation Example sections for how to configure this
parameter.
Because this parameter can also be set by the DIP switches, you may need to ensure that the DIP switches are
set to
Software
configuration mode; if they are set to
Hardware
, the front panel menu will be able to display but
not change these settings.
Reset to Default Settings
The final option that comes up in the menu is Reset to Default Settings. To select this function, release the mode
switch when the red LED starts flashing.
Note.
Resetting to default settings can also be done using Click Supervisor.
This function will restore all configuration settings to factory defaults, even those parameters not configured using
the front panel menu: baud rate, channel input map, description field, location field, and device ID.
Level 1 LEDs
Reset to default settings
Level 2 LEDs
Cancel and exit menu
LED off
Reset to default settings
LED on
See the earlier Navigating through the Menu and the Menu Operation Example sections for how to view this
parameter.
After the Click 112/114 has reset to factory defaults, it will check the DIP switches; if any of them are set to
Hardware
mode, it will apply those settings to the parameter in question. If resetting to factory defaults doesn’t
change certain settings the way you expected it to, check the DIP switches to see if they are causing settings to
be changed to something other than the default.
Click Supervisor
Click Supervisor is the only way to configure non-data path type parameters such as the description, location, and
device ID. See the knowledge base article
0514 Installing and Using Click Supervisor
for instructions on how to
download and install Click Supervisor and how to connect to your device using the software.
Note.
Some of the parameters mentioned below can only be configured in Click Supervisor. Others can be
configured by the front panel menu and/or the DIP switches. In the case of the DIP switches, if that parameter is
set to
Hardware
mode, it will be grayed out in Click Supervisor, meaning you can view but not change the setting.
If you would like to set it using Click Supervisor, you will have to turn off all those switches on the device.
The Click 112/114 can be configured using the Expert driver (see the figure below).