Click 514 Event Logger
INSTALLATION QUICK START GUIDE
1
Mount the device
The Click 514 mounts over a T-bus for power and communication:
1
If the Click 514 was shipped with the T-bus connector attached, remove the connector
from the module.
2
Snap the connector onto the DIN rail by positioning it over the rail with the male connector
pointing to the right. Hook one arm over the edge of the DIN rail and press down on the
other arm until it snaps into place.
3
Connect the T-bus connector to the rest of the T-bus by sliding them together until you
hear them snap into place.
4
Mount the Click 514 onto the DIN rail: position it properly over the T-bus connector, hook
the lip over the lower edge of the DIN rail, and use a rocking motion to snap the module
into place.
2
Wire power and communication
If you are using a Click 200 surge protector with the Click 514, power and communication are provided to the Click 514
through the T-bus (see the Click 200 Quick Start Guide). If you don’t have a Click 200 surge protector, use the following steps
to wire power and communication into the Click 514:
1
Plug a T-bus 5-screw terminal block into the first T-bus connector.
2
Wire DC power (10–30 V) from the power supply into the first screw terminal on the 5-screw terminal block; wire -DC into
the second screw terminal.
3
Connect RS-485 communication (+485, -485, and GND) to either the remaining thee screw terminals on the 5-screw ter-
minal block or to the screw terminals in the pluggable screw termi-
nal block on the top of the Click 514 (see labels for correct wiring).
The Click 514 has three other communication ports.
˽
RJ-11 jack –
Connect a jumper cable here for RS-485 communication
˽
DB-9 connector –
Connect a straight-through cable here for RS-232
communication
˽
RS-232/RS-485 terminals –
On top of device; usually not used
Note.
The Click 514 has been specifically designed to work with the
Acumen DataBridge SDR2-CF device. The DataBridge can be used to record several gigabytes of data onto a compact flash
card on a daily, hourly, or continuous basis.
Red (+DC)
Black (-DC)
White (+485)
Blue (-485)
Drain (GND)