background image

WX-500-0317

© 2020 Wavetronix LLC. All rights reserved. Protected in the US by patents viewable at www.wavetronix.com/en/legal. Protected by Canadian Patent Nos. 2461411; 2434756; 2512689; and European Patent Nos. 1435036; 

1438702; 1611458. Other US and international patents pending. Wavetronix, SmartSensor, Click, Command and all associated logos are trademarks of Wavetronix LLC. All other product or brand names as they appear are 

trademarks or registered trademarks of their respective holders. Product specifications are subject to change without notice. This material is provided for informational purposes only; Wavetronix assumes no liability 

related to its use.

Once the device has been configured, use Programming mode to automatically program 

the DataBridge SDR2-CF device.

Remove the serial cable from your computer.

Connect the cable to the configuration port of the DataBridge using a Null modem 

adapter and a male-to-male gender changer.

Hold the Click 514 push-button down, then release when the yellow LED turns on.

Press the push-button to select. The yellow LED bank will light up, indicating programming.

When the yellow LED bank turns off and the record LED on the DataBridge lights up, 

programming is complete.

7

  Logging mode

8

  Retrieve data

To retrieve the data that has been selected, remove the compact flash card from the Data-

Bridge and transfer the log files to your computer using a compact flash reader. The data files 

are in a tabular format that imports easily into programs like 

Notepad and Excel. The following information is given:

Next, the device needs to be set to run in logging mode.

Remove the null cable and use a straight-through serial cable to connect to the DataBridge from your computer. 

One the Click 514, hole the push-button down, then release when the blue LED turns on.

Press the push-button to select.

When the yellow LED bank turns off and the record LED on the DataBridge lights up, programming is complete.

While in logging mode, all vehicle detections generated by the SmartSensor HD will be recorded according to the logging 

settings selected in setup mode. Each time a SmartSensor HD detection is pushed onto the Click 514, you should see the 

Yellow 1 LED on the Click device and the data light on the DataBridge light up.

6

  Programming mode

 

˽

Date

 

˽

Time

 

˽

Lane

 

˽

Speed

 

˽

Length

 

˽

Range

 

˽

Class

 

˽

Duration

To reset the Click 514, follow the steps below:

Hold the push-button down, then release when the red 

LED starts flashing.

Press the push-button to select. The first yellow LED will 

turn on to let you use that submenu.

Hold down the push-button again to cycle between the 

following options:

 

˽

Yellow 1 –

 Resets all settings except Serial Number 

and XML variable map

 

˽

Yellow 2 –

 Resets all settings except Serial Number

Release when you reach the one you want. Press the 

push-button to select.

After the device is reset, it will return to the last mode it was in.

9

  Reset

Reviews: