105
Inovonics Interface Event Processing Enabled Configuration
•
Starting with no Data Connections, create Data Input using Inovonics protocol
•
Create Data Connection between Inovonics data input and Event Processing data output
•
Create Smartphone data output
•
Create Data Connection between Event Processing data input and Smartphone data output
•
Inovonics sensors, Inovonics central receiver and Inovonics repeaters auto-register with RMS
•
Name the Inovonics repeaters in the Facility/Wireless Receivers page
•
Name the Inovonics sensors in the Alert Sources/Inovonics Sensors page, using either the Name
field or the Reference field
•
To configure an escalation management system, enable Event Processing in Setup/General
Settings page, and adjust the Slow Response Threshold and Backup Response Threshold values
in that page
•
Create one or more Zones in the Zones page, where one or more of those Zones can be used as
Backup Zones
•
Associate Backup Zones with your primary Zones using the Zones/Backup Zones page
•
Associate Inovonics sensors with any primary Zones using the Zones/Inovonics Sensors page
•
Log in with all of the Responder 5000 app Extension values to create the required User Accounts
in the system
•
Associate User Accounts with your primary Zones and backup Zones using the Zones/User
Accounts page
Inovonics User Experience with Event Processing Enabled
When an Inovonics sensor alert is initiated, all logged-in Responder 5000 app users that are associated
with the same Zone as the active Inovonics sensor will receive those alerts. Those logged in Responder
5000 app users associated with other Zones will not receive those alerts.
The alert will appear on the app as a non-answerable notice, with the Name/Reference value of the
Inovonics sensor in the Message field and the Name value of the nearest receiver appears in the
Location field.
That alert persists on the Responder 5000 app until either Acknowledged by the app user or until the
Inovonics sensor is physically reset.
When the Slow Response Threshold value for a given active alert is exceeded, that alert will be delivered
to any logged-in Responder 5000 app users that are associated with any backup zones associated with
the primary Zone that the Inovonics sensor is associated with.
If there are no Backup Zones assigned to the affected primary Zone, that alert will be delivered to any
User Account that is marked to receive Supervisory Alerts, using all communication methods associated