[4]
MODELS & FEATURES
CURRENT SYSTEMS
Figure 2: Current Paging System Comparison
Model No.
Serial
Ports
Ethernet
Sockets
Paging Transmission
Wattage
Duty Cycle
Range
Serial
Config.
Web
Config.
SPS5 v9E
1
2
2 or 5 Watts
30% - 70%
Y
Y
SPS5 v9S
1
0
2 or 5 Watts
30% - 70%
Y
N
SPS5 v9E-XL
1
2
5 Watts
100%
Y
Y
SPS v9E-HP
1
2
10 - 25 Watts
80%
Y
Y
LEGACY SYSTEMS
These legacy systems will not be discussed in this manual, but they are able to be used with the
WaveWare V9 Encoder Setup Software v9.3.xx.
Figure 3: Legacy System Comparison
Model No. Serial
Ports
Ethernet
Sockets
Paging Transmission
Wattage
Recommended
Duty Cycle Range
Serial
Config.
Web
Config.
SPS5 v9
2
0
2 or 5 Watts
30%-70%
Y
N
SPS5 v8
1
0
2 or 5 Watts
30%-70%
Y
N
FEATURES & CAPABILITIES
The capabilities of the SPS5 Series Paging Systems is standard across the board with the exception of
the
SPS5 v9S and Legacy Systems: These do not have an Ethernet Port and thus cannot be configured or
receive messages over IP
. Below is a comprehensive list of the features and capabilities you can expect
from your WaveWare V9 Series Paging System:
•
SERIAL PORT CONTROLLED OPERATION
via the RS-232 Serial Port with programmable
communication parameters. Valid serial baud rates are: 300, 1200, 2400, and 9600, with None, Even,
or Odd parities. Default setting is 9600-None, unless specified differently by a customer requirement.
•
UHF & VHF BANDS
WaveWare has FCC Shared-Use Licenses for different frequencies in the UHF
band (450-470 MHz). For VHF or any UHF frequencies we do not own, we can handle your site’s
application to the FCC for a fee. This only applies to U.S. installations.