ATI Keepalive Mode 

The ATI Keepalive setting displays whether or not the ATI Keepalive feature is enabled in the STG.  When 
the ATI Keepalive mode is enabled in the STG, the STG will output an ATI<CR> to each of the TAP outputs 
once per minute and monitor for any response.  If no response occurs, the STG will log a communication 
failure event and change the status field value in the configuration screen to 

Trying to Login

, and will 

attempt to log back into the paging system.  WaveWare paging systems always respond to ATI<CR> 
prompts. 

Legacy Dial Back 

The Legacy Dial Back setting cause the STG to format all TAP paging messages using the Rauland Legacy 
Dial Back method.  Following is an example showing the difference between the normal and Legacy Dial 
Back methods of formatting TAP paging messages. 

4West402:1 Patient OT

 is normal TAP message formatting

 

4*402*1 Patient OT

 is Legacy Dial Back TAP message formatting 

Demo Mode 

The Demo Mode setting causes the STG to output demonstration TAP paging messages, at the rate of 
one message every 2 seconds.  The purpose of the Demo Mode is to allow the TAP compatibility testing 
to occur without requiring a Rauland nursecall system or a Brekeke SIP Server.   

Following is an example of how the demo TAP paging messages are logged by the STG: 

Fri Sep 16 2016 16:39:09 GMT-0500 (Central Daylight Time) 

PagerId:

 101 

Message:

 1Demo101:1 

Patient OT 

 

===================================== 

INTERNALLY GENERATED DEMO MESSAGE  

===================================== 

The STG will always output demo messages using a Pagerid value of 101, with the Message formatted as 
1Demo10N:1 Patient OT, where the N value cycles from 1 to 5 repeatedly. 

Demo Mode will continue until disabled and the STG restarted via the STG main browser page. 

Note that the STG will process SIP messages simultaneously with Demo Mode operation. 

System Status Table 

The STG System Status table is displayed in the STG configuration page.  The System Status Table is 
updated automatically as system status changes.  The System Status Table indicates the state of the SIP 
Input, and any Ethernet and/or Serial Port Paging Systems.   

The first column of the System Status Table identifies the STG system element, including Sip Input, USB0, 
USB1, USB2, USB3, and IP.  Records for these elements appear if they are detected on startup or 
dynamically during operation.  The Ethernet Paging System record is created when an IP address and IP 
port are defined for the Ethernet Paging System and recognized on startup of the STG.  The Serial Port 
Paging System records are automatically created when the STG detects USB to Serial Port adapters being 
connected or disconnected from the STG, and upon startup. 

Summary of Contents for STG

Page 1: ...are Discover and Reset Tool 4 Configure the STG 5 Save the STG Settings 7 Restart the STG 7 Configuration 7 DHCP 7 STG IP Address 8 Subnet Mask 8 Gateway IP 8 Time Server 8 Ethernet Paging System IP A...

Page 2: ...ool 14 Troubleshooting Problems During Software Update Process 14 Examining STG Log Data 14 Sip Input Data Log 14 Restarting the STG 15 STG Throughput Capabilities 15 Adjusting the STG Boot Up Method...

Page 3: ...port controlled paging systems or downstream devices that process TAP protocol Note When connecting WaveWare paging systems to the STG USB ports you will need a Belkin USB to Serial Portable Adapter...

Page 4: ...e Discover and Reset Tool Note WaveWare Discover and Reset Tool requires Microsoft NET runtime files to be installed on the PC that will be used to run the app Connect a Windows PC running the WaveWar...

Page 5: ...that the STG is connected to does not allow UDP broadcast packets then the WaveWare Discover and Reset Tool will not discover the STG Refer to Troubleshooting section for how to address this issue Con...

Page 6: ......

Page 7: ...iguration page 3 The STG is hard coded to listen for SIP UDP communications on IP port 5060 4 The Serial Paging Systems configuration values apply to all connected Serial Paging Systems Typical Serial...

Page 8: ...g System IP Address field displays the currently assigned IP address for any Ethernet paging system that you want the STG to communicate to If you do not want the STG to try to communicate to an Ether...

Page 9: ...r Following is an example of how the demo TAP paging messages are logged by the STG Fri Sep 16 2016 16 39 09 GMT 0500 Central Daylight Time PagerId 101 Message 1Demo101 1 Patient OT INTERNALLY GENERAT...

Page 10: ...script retrieval the system restarts and applies the update script This feature requires the STG to have internet access Note that the update process can take up to 25 minutes and the STG should not b...

Page 11: ...STG related log entries will show that each session was terminated by a 404 error as shown in the figure below That is normal due to the need to use 404 Not Found signaling to the Responder so that t...

Page 12: ...discovered STG a popup window will occur that tells you that you need to reset the STG Resetting an STG primarily enables DHCP mode in the STG and restarts the STG To reset an STG click on the reset...

Page 13: ...input or output to review the communications on each of the input and or outputs as an additional means of troubleshooting communications You can e mail all or part of a particular Data Log to WaveWa...

Page 14: ...so that the router can provide DHCP services to the STG Run WaveWare Discover and Reset Tool on the laptop to discover the STG 3 Attach a video monitor to the HDMI port or mini DisplayPort on the STG...

Page 15: ...the button on top of the STG observe the LED in the button to start blinking wait several seconds for the illumination of the button to stop then press the button again to restart the STG STG Through...

Page 16: ...e Power tab The options are Power On Stay Off Last State The STG should be configured to use the Power On option which allows a full boot up process to automatically occur each time power is applied I...

Page 17: ...tion with the paging system If the odd response is ID the STG will respond with ESC PG1 CR For any other odd response the STG will respond with BYE CR then will output a CR every 3 seconds if the ID r...

Page 18: ...TAP over Ethernet output driver to correct a long term socket connectivity issue V1 08 Modified TAP output driver to alternately output BYE CR and CR at the beginning of any new paging system connect...

Reviews: