15
Finally (unless performed earlier), the current hyper terminal configuration can be saved for more convenience,
i.e. you don’t have to reconfigure the interface for each new hyper terminal session.
Figure 13: Establishing communication with the hyper terminal: saving a communication session
4.2 Online-Help
Once communication has been established with a PC (as described above), an online help tool can be called up
by triggering an ID [Enter] or id [Enter] command at the keypad. Its purpose is to support work with distance
measurement and parameterization commands. [Enter] corresponds to hexadecimal 0Dh (carriage return)
DT[Enter]
distance tracking
DS[Enter]
distance tracking 7 m
DW[Enter]
distance tracking with cooperative target (10 Hz)
DX[Enter]
distance tracking with cooperative target (50 Hz)
DF[Enter]
distance measurement with external trigger
DM[Enter]
distance measurement
TP[Enter]
internal temperature [C]
SA[Enter]/SAx [Enter]
display/set average value [1...20]
SD[Enter]/SDd[Enter]
display/set display format [d/h]
ST[Enter]/STx[Enter]
display/set measure time [0...25]
SF[Enter]/SFx.x[Enter]
display/set scale factor
SE[Enter]/SEx[Enter]
display/set error mode [0/1/2]
0...I
out
=const., ALARM=const.
1...I
out
: 3 mA @RE>RB, 21 mA @RE<RB,
ALARM: OFF@AH>0, ON@AH<0
2...Iout: 21 mA @RE>RB, 3 mA @RE<RB,
ALARM: ON@AH>0, OFF@AH<0
AC[Enter]/ACx.x[Enter]
display/set ALARM center
AH[Enter]/AHx.x [Enter]
display/set ALARM hysteresis
AW[Enter]/AWx.x [Enter]
display/set ALARM width
RB[Enter]/RBx.x[Enter]
display/set distance of I
out
=4 mA
RE[Enter]/REx.x[Enter]
display/set distance of I
out
=20 mA
RM[Enter]/RMx y.y z[Enter]
remove measurement
TD[Enter]/TDx y[Enter]
display/set trigger delay [0...9999 ms] trigger level [0/1]
TM[Enter]/TMx y[Enter]
display/set trigger mode [0/1] trigger level[0/1]
BR[Enter]/BRx[Enter]
display/set baud rate [2400...38400]
AS[Enter]/ASd[Enter]
display/set autostart command
[DT/DS/DW/DX/DF/DM/TP/LO/ID]
OF[Enter]/OFx.x[Enter]
display/set distance offset
SO[Enter]
set current distance to offset (offset = - distance)
LO[Enter]
laser on
LF[Enter]
laser off
PA[Enter]
display settings
PR[Enter]
reset settings