Please note that the WBA2 magnetic tape can be equipped with a stainless-steel cover strip (provided in
delivery) to protect its magnetic surface. Therefore, the distance between sensor and tape is different whether
the cover strip is applied or not.
The following table shows the range within which the distance between sensor and magnetic tape must be:
Distance (D) between sensor and magnetic tape...
...without cover strip
...with cover strip
0.1...0.6 mm
0.1...0.4 mm
After the installation of the sensor and the magnetic tape a zero-setting / Preset operation is required. The
zero-setting / Preset operation is further required every time either the sensor or the tape is replaced. This
operation is only available for sensors with BiSS interface. It is not available for the SSI interface.