background image

INSTALLATION GUIDE

Draw wire sensors series SX50,  SX80, SX120

For further information please see the data sheet at www.waycon.biz/products/draw-wire-sensors

FIRST STEPS

WayCon Positionsmesstechnik GmbH would like to thank you for the trust you have placed in us and our 
products. This manual will make you familiar with the installation and operation of our draw wire sensors. 
Please read this manual carefully before initial operation!
Unpacking and checking:
Carefully lift the device out of the box by grabbing the housing. Do not pull the rope. After unpacking the 
device,  check  it  for  any  visible  damage  as  a  result  of  rough  handling  during  the  shipment.  Check  the 
delivery for completeness.
If necessary consult the transportation company, or contact WayCon directly for further assistance.

MOUNTING OF THE SENSOR

Mount the sensor at the designated place by using the fixing holes before extracting the rope and before 
attaching the rope to the measuring target.
The  sensor  is  usually  installed  by  using  the  regular  mounting  plate.  By  disassembling  the  mounting 
plate,  4  threads (2  x  M3,  2  x  M5)  will  become  visible in the sensor housing  for  alternative  installation. 
Sensors with option rope outlet S2 and S3 have a modified base plate.
Open the rope clip after the sensor is fully mounted and carefully extract the measuring rope. Hook the 
rope clip on the measuring target and close the bracket of the clip. For safety reasons put a screw driver 
through the clip to extract the rope

.

HANDLING THE WIRE ROPE

When installing or operating the sensor, take care not to let the rope snap back by mistake or extract the 
rope over the specified measurement range, as this might destroy the sensor.
The  rope  must  be  extracted  from  the  sensor  vertically. The  maximum  variation  from  the  vertical is 3°. 
Avoid carefully extracting the rope at an inclination, since the durability of the instrument would shorten 
considerably. If it is not possible to keep the limit of 3°, a deflection pulley has to be used.
Guide the rope preferably in corners or guarded in channels to prevent pollution or accidental touch.
Avoid guiding the rope over edges or corners. Use a deflection pulley instead.
Do not operate the sensor if the rope is buckled or damaged. A ripping of the rope may lead to injuries or 
a damaging of the sensor.

WARNING NOTICES

Manufacturer

WayCon Positionsmesstechnik GmbH
Mehlbeerenstrasse 4
82024 Taufkirchen / Germany

This is to certify that the products

Classification

draw wire sensors

Product series

SX

fulfill the current request of the following EC-directives:
EMC-directive

2004/108/EC (until April 19th, 2016) 
2014/30/EU (from April 20th, 2016) 

applied harmonized standards:
IEC 61326-1:2013 

The declaration of conformity loses its validity if the product is misused or modified without proper 
authorisation.

Taufkirchen, 24.02.2016

Andreas Täger
CEO

DECLARATION OF EC-CONFORMITY

Do  not  try  to  open  the  device.  The  stored  energy  of  the  spring  drive  may  lead  to  injuries  when
being mishandled.
Do not touch the rope when operating the sensor.
When  mounting  outdoors  protect  the  sensor  and  the  rope  from  icing  at  temperatures  below  0  °C. 
The usage of a deflection pulley may help defrosting the wire rope.
When operating the sensor in a humid environment, install the sensor with the rope outlet downwards. 
Otherwise water will gather inside the housing, which leads to corrosion. 
Where applicable use option S3.

MAINTENANCE

The devices are maintenance-free. If however, the rope is soiled due to adverse environmental 
conditions, it can be cleaned with a cloth drenched in resin-free machine oil

.