INSTALLATION GUIDE
Draw wire sensors series SX50, SX80, SX120
For further information please see the data sheet at www.waycon.biz/products/draw-wire-sensors
FIRST STEPS
WayCon Positionsmesstechnik GmbH would like to thank you for the trust you have placed in us and our
products. This manual will make you familiar with the installation and operation of our draw wire sensors.
Please read this manual carefully before initial operation!
Unpacking and checking:
Carefully lift the device out of the box by grabbing the housing. Do not pull the rope. After unpacking the
device, check it for any visible damage as a result of rough handling during the shipment. Check the
delivery for completeness.
If necessary consult the transportation company, or contact WayCon directly for further assistance.
MOUNTING OF THE SENSOR
Mount the sensor at the designated place by using the fixing holes before extracting the rope and before
attaching the rope to the measuring target.
The sensor is usually installed by using the regular mounting plate. By disassembling the mounting
plate, 4 threads (2 x M3, 2 x M5) will become visible in the sensor housing for alternative installation.
Sensors with option rope outlet S2 and S3 have a modified base plate.
Open the rope clip after the sensor is fully mounted and carefully extract the measuring rope. Hook the
rope clip on the measuring target and close the bracket of the clip. For safety reasons put a screw driver
through the clip to extract the rope
.
HANDLING THE WIRE ROPE
When installing or operating the sensor, take care not to let the rope snap back by mistake or extract the
rope over the specified measurement range, as this might destroy the sensor.
The rope must be extracted from the sensor vertically. The maximum variation from the vertical is 3°.
Avoid carefully extracting the rope at an inclination, since the durability of the instrument would shorten
considerably. If it is not possible to keep the limit of 3°, a deflection pulley has to be used.
Guide the rope preferably in corners or guarded in channels to prevent pollution or accidental touch.
Avoid guiding the rope over edges or corners. Use a deflection pulley instead.
Do not operate the sensor if the rope is buckled or damaged. A ripping of the rope may lead to injuries or
a damaging of the sensor.
WARNING NOTICES
Manufacturer
WayCon Positionsmesstechnik GmbH
Mehlbeerenstrasse 4
82024 Taufkirchen / Germany
This is to certify that the products
Classification
draw wire sensors
Product series
SX
fulfill the current request of the following EC-directives:
EMC-directive
2004/108/EC (until April 19th, 2016)
2014/30/EU (from April 20th, 2016)
applied harmonized standards:
IEC 61326-1:2013
The declaration of conformity loses its validity if the product is misused or modified without proper
authorisation.
Taufkirchen, 24.02.2016
Andreas Täger
CEO
DECLARATION OF EC-CONFORMITY
Do not try to open the device. The stored energy of the spring drive may lead to injuries when
being mishandled.
Do not touch the rope when operating the sensor.
When mounting outdoors protect the sensor and the rope from icing at temperatures below 0 °C.
The usage of a deflection pulley may help defrosting the wire rope.
When operating the sensor in a humid environment, install the sensor with the rope outlet downwards.
Otherwise water will gather inside the housing, which leads to corrosion.
Where applicable use option S3.
MAINTENANCE
The devices are maintenance-free. If however, the rope is soiled due to adverse environmental