background image

INSTALLATION GUIDE

Ultrasonic Sensor Series UFA2, UFA-CP and UFA-6000

For further information please see the data sheet at www.waycon.biz/products/ultrasonic-sensors/

FIRST STEPS

WayCon Positionsmesstechnik GmbH would like to thank you for the trust you have placed in us and 

our products. This manual will make you familiar with the installation and operation of our ultrasonic 

sensors. Please read this manual carefully before initial operation!

Unpacking and checking:

Carefully lift the device out of the box by grabbing the housing. After unpacking the device, check 

it for any visible damage as a result of rough handling during the shipment. Check the delivery for 

completeness. If necessary consult the transportation company, or contact WayCon directly.

SAFETY NOTICES

•  These products are neither allowed to be used as safety- or emergency shut-off devices, nor in other 

applications, where a malfunction of this product may result in personal injury. 

•  Failure to follow this notice may result in serious or fatal injury.

MOUNTING NOTICES

•  The sensor can be mounted with the two M12 nuts (UFA2/UFA-CP) or M30 nuts (UFA-6000) which 

are included in the delivery.

•  The sensor has to be protected against mechanical loads for example shocks and impacts.

•  The sensor can be mounted in any position, however a vibration-free or vibration-dampening 

assembly must be observed.

•  The transducer surface as well as the field of the detection beam must be kept free mandatorily. You 

need to pay attention on having no disturbing objects between the sensor and the target object 

within the detection beam. Otherwise the sensor will detect the disturbing object instead of the 

target object required.

•  The object reflects a part of the ultrasonic in the 

diffuse mode - this reflected sound will be evaluated 

by the sensor. Objects with a smooth surface are 

reliably detected up to a tilting angle of approx. 10°. 

The max. allowed tilting angle increases on objects 

with a rough or heavy structured (granular) surface.

Summary of Contents for UFA-CP Series

Page 1: ...a malfunction of this product may result in personal injury Failure to follow this notice may result in serious or fatal injury MOUNTING NOTICES The sensor can be mounted with the two M12 nuts UFA2 UF...

Page 2: ...o teach points The output signal is scaled to the taught measuring range Procedure 1 Place the target on the position of the 1st teach point i e where 0 V or 4 mA should be output 2 Connect the teachi...

Page 3: ...with V Pin 1 for 2 4 s LED flashes slowly 1 Hz 3 Within 20 s remove the target and connect the teaching line with V for 2 4 s 4 LED flashes 2 times teach procedure successful LED flashes 4 times teac...

Page 4: ...wire must not be connected during normal operation Those the sensor can be operated after teaching with a 3 wire cable TEACHING FUNCTION UFA 150 CP SWITCHING OUTPUT Setting of the switching points Th...

Page 5: ...andTeach B see drawing below In such setup the sensor detects also targets which pass the sensor beam in a very flat angle The sensor would not detect such targets in normal scan operation mode teach...

Page 6: ...225 0 5 10 15 5 10 15 blind range target plate 100 x 100 mm target round bar 10 mm UFA2 FB 150 Focus beam version 0 20 40 60 100 80 120 140 160 0 5 10 15 5 10 15 20 20 target plate 20 x 20 mm target...

Page 7: ...xis so that the echo is weakened or can no longer be received at all For convex cylindrical and spherical surfaces every area element has a different angle to the sound cone s axis The reflected cone...

Page 8: ...correspond to the mentioned specifications Classification Ultrasonic Sensors Series UFA 150 CP UFA2 UFA 6000 Test on immunity IEC 61000 6 2 Industry Type of test applied harmonized standards EN 61000...