SPECIFICATIONS

POWER SUPPLY REQUIREMENTS

120 or 230 V, 60 Hz

MOTOR 

                           Split Phase

HORSEPOWER 

 1 HP .................... (CWS100) 

 3/4 HP  ................ (CWS75)
 1/2 HP...................(CWS50)

LIQUID TEMPERATURE RANGE

40° F- 120° F

CUT IN PRESSURE

30 PSI

CUT OUT PRESSURE

50 PSI

640000-001 B 08/18

© 2018, WAYNE/Scott Fetzer Company.

CONSTRUCTION

MOTOR HOUSE

Cast Iron

SEAL PLATE

Cast Iron

DIFFUSER

Thermoplastic

IMPELLER

Thermoplastic

SHAFT

Carbon Steel

PUMP SUCTION

1-1/4 in. NPT

PUMP DISCHARGE

3/4 in. NPT

Convertible Well Jet Pump Water Systems

www.waynepumps.com

PERFORMANCE

Model

HP PSI 0 ft 

 

10 ft  20 ft  30 ft 40 ft 50 ft 60 ft 70 ft 80ft 90 ft

CWS100

1

30

1056

948

846

750

642

516

384

294

234

180

40

840

750

642

528

384

294

234

180

126

72

50

588

444

330

264

234

180

126

72

-

-

CWS75

3/4

30

990

906

774

630

510

408

306

246

186

54

40

780

630

510

408

306

246

186

114

54

-

50

462

330

270

216

156

90

-

-

-

-

CWS50

1/2

30

900

780

690

570

456

348

270

180

90

-

40

660

570

450

348

270

180

90

-

-

-

50

408

300

210

150

60

-

-

-

-

-

Intended for Indoor Use Only

Please read and save these instructions. Read carefully before attempting to assemble, install,

operate or maintain the product described. Protect yourself and others by observing all safety

information. Failure to comply with instructions could result in personal injury and/or property

damage! Retain instructions for future reference.

Operating Instructions and Parts Manual 

 

                   CWS Series

* Refer to Page 13 for Jet Assembly Part Numbers

Summary of Contents for CWS Series

Page 1: ...56 948 846 750 642 516 384 294 234 180 40 840 750 642 528 384 294 234 180 126 72 50 588 444 330 264 234 180 126 72 CWS75 3 4 30 990 906 774 630 510 408 306 246 186 54 40 780 630 510 408 306 246 186 11...

Page 2: ...qui si elle n est pas vit e pourrait entra ner des blessures mineures ou mod r es Notice indicates important information that if not followed may cause damage to equipment This is the safety alert sy...

Page 3: ...on annuler la garantie All wiring should be performed by a licensed or certified electrician Tout c blage doit tre r alis par un lectricien agr ou certifi 10 Make sure the line voltage and frequency o...

Page 4: ...LLATION LOCATION Select a location as close to the water supply as possible Be sure to comply with any state or local codes regarding the placement of the pump The equipment must be protected from the...

Page 5: ...ng air Sloping the pipe will also aid in priming the pump DRIVEN WELL FIGURE 16 PAGE 13 Drive the point several feet below the water table NOTE A packer type foot valve can be installed in the well Fi...

Page 6: ...tall the horizontal pipe from the well to the pump Piping from the vertical well pipe to the pump should never be smaller than the well pipes 7 Slope both pipes upward toward the pump to prevent trapp...

Page 7: ...ainst inside of the well casing It may be necessary to move the jet up and down to seat the cups 6 Install the casing adapter and the horizontal pipes 7 Slope both pipes upward toward the pump to elim...

Page 8: ...etween the system and the house plumbing to aid in pump removal for servicing and for reducing noise transmitted to the house through the piping 4 Provide a faucet at the lowest point in the system to...

Page 9: ...round connection must be made at this terminal Figure 9 The ground conductor must not be smaller than the circuit conductors supplying the motor The voltage of power supply must match the voltage of t...

Page 10: ...endommager la pompe ne pas d marrer le moteur tant que la pompe n a pas t remplie d eau 1 Remove prime plug 2 Fill pump and piping completely full of water 3 Replace the prime plug 4 Close the contro...

Page 11: ...ssurized water in the system 3 Prime the pump See Priming the Shallow Well or Priming the Deep Well Sections 4 Reconnect the power to the pump NOTE As the pump refills the tank with water the air volu...

Page 12: ...be orientated during assembly so the two holes are on a horizontal line across the motor shaft Figure 14 18 Push the bellows side of the shaft seal over the impeller hub you can use a little water or...

Page 13: ...or concrete to prevent cave in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through 2 E DR...

Page 14: ...d 5 Well screen or inlet strainer clogged 5 Clean or replace as necessary 6 Clogged nozzle deep well 6 Pull jet and clear obstruction 7 Air volume control diaphragm ruptured 7 Replace air volume contr...

Page 15: ...Harrison OH 45030 U S A 1 REPLACEMENT PARTS Ref No Description Models Qty CWS50 CWS75 CWS100 1 2 Square Ring Gaskets Impeller Jet Pump Dissfuser and Shaft Seal Assembly 64046 WYN1 CWS50 64047 WYN1 CW...

Page 16: ...DING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE WITH RESPECT T...

Reviews: