background image

 

 
 
 

 

 

© Copyright  

2008-03-20  V0  Rev.01.0

 

- 4 - 

WT004139 

 

 

The descriptions and illustrations in this manual are not binding.  
DRESSER reserves the right to make any modifications it considers necessary to make technical improvements 
or  for  any  other  structural  or  commercial  reason,  at  any  time  and  without  having  to  update  the  present 
publication. Modifications will not compromise the essential characteristics of the equipment.  

 

 

 
 

General Warnings 

 

 

Before  using  this  equipment,  read  carefully  the  instructions  in  this  manual  in  order  to  effectuate  a 
correct carry out transportation, start-up and ordinary maintenance.   

 

Dresser is not responsible for any operations not listed in this manual. In case of breakdown, failure or 
malfunction, refer exclusively to the Maintenance Company or Dresser itself.   

 

Dresser  declines  responsibility  for  any  damage  to  things  and/or  persons  due  to  non-compliance  with 
safety rules.   

 

The safety rules in this manual are an integration and not a replacement of the laws in effect in those 
countries  where  this  equipment  is  installed.  It  is  assumed  that  the  station  operators  have  full 
knowledge of the safety rules of the country where they operate.   

 

In case of doubts regarding the proper functioning of the equipment, please refer to the maintenance 
company or to Dresser itself to obtain any necessary instructions.   

 

In case of breakdowns and/or malfunctions of the pump or of its components, refrain from performing 
any  intervention  that  may  compromise  the  safety  of  the  equipment.  Refer  exclusively  to  the 
maintenance company of Dresser itself.   

 

Periodically  check  the  safety  devices  in  compliance  with  the  instructions  of  this  manual  and  ensure 
they are in perfect condition.   

 

Dresser will not be held responsible for any tampering performed by the customer, who in this case will 
be the only party held liable by the competent authorities.    

 

For further information on the main components of the equipment (mass flow meter, actuator, board, 
etc)  and/or  original  spare  parts,  see  the  specific  technical  documentation  given  to  your  technical 
assistance/after-sales company.   

 

Warnings for fuel station operators 

 

 

The station manager and attendant must carefully read this manual before starting the equipment. We 
also  recommend  keeping  this  manual  throughout  the  operational  life  cycle  of  the  equipment,  without 
adding or modifying anything.    

 

The  customer  will  be  held  responsible  for  any  damages  due  to  corrosion,  incrustation,  pollution, 
oxidation,  dust,  wear-and-tear  and  gradual  deterioration  of  the  product  for  which  conformability  limits 
have not been set. The customer will also be responsible for any damages related to improper use or 
maintenance  of  the  product.  Furthermore  the  customer  will  also  be  responsible  for  any  damages 
caused by any modifications to the product without prior consent by Dresser, in particular modifications 
that are not compliant to what was established in the initial purchase order. 

 

The  use  of  non-original  spare  parts  by  the  customer  will  discharge  Dresser  from  any  responsibilities 
and from any compensation.   

 

The GLOBAL VISTA CNG dispenser has the 

 marking guaranteeing that the equipment has been 

manufactured  in  conformity  with  the  applicable  EU  directives.  The  dispenser  leaves  the  factory 
equipped with the CE declaration of conformity (see the last page of this manual). The CE declaration, 
just  like  this  manual,  must  be  kept  and  shown  upon  request  by  the  competent  authorities,  in  case of 
inspections  and/or  tests.  Any  modifications  to  the  product  that have not been previously approved by 
Dresser will invalidate the declaration of conformity.  

  

 
 
 
 
 
 

 

Summary of Contents for GLOBAL VISTA CNG

Page 1: ...EN WT004139 2008 03 20 V0 Rev 01 0 Global Vista CNG Instruction Manual ...

Page 2: ...ния перед началом любых работ Warning Never run a leaking pump Be careful with the environ ment and mind the skidding risk take care of leaking fuel immediately Varning Använd aldrig en läckande pump Tänk på miljön och halk risken sanera utläckt driv medel snarast Warnung Lassen Sie nie eine undichte Zapfsäule laufen Seien Sie umweltbewusst und denken Sie an die Rutschgefahr beseitigen Sie austret...

Page 3: ...stallation 9 Initial start up 16 Dispensing procedure 16 COMPONENTS 17 Hydraulic components 17 Electrical components 17 HYDRAULIC COMPONENTS 18 Manual ball valve 18 Particulate filter 18 Check valve 18 Mass flow meter 18 Motorized valve 18 Pressure gauge 18 Delivery hose 18 Delivery Nozzle 18 Three way valve 19 Breakaway Device 19 ELECTRICAL COMPONENTS 19 Electronic head 19 Electrical components u...

Page 4: ...Dresser will not be held responsible for any tampering performed by the customer who in this case will be the only party held liable by the competent authorities For further information on the main components of the equipment mass flow meter actuator board etc and or original spare parts see the specific technical documentation given to your technical assistance after sales company Warnings for fu...

Page 5: ... positions of these warnings depend on local conditions but they must be visible from the dispenser Ensure that all station attendants know how to behave in an emergency situation Protection from pressure related risks The hydraulic circuit of the dispenser works under pressure Before performing any maintenance accurately close the cut off valve s located at the base of the dispenser and release t...

Page 6: ...e prohibit or restrict access to the switches used to interrupt power supply to the dispenser Ensure that the fuelling station has both an electrical line equipped with an automatic breakaway device as well as a proper grounding system in compliance with all applicable regulations Dispenser Identification The GLOBAL VISTA CNG dispenser can be manufactured in different versions due mainly to the di...

Page 7: ...the mass flow meter in the dispenser The information given by the mass flow meter or any other sensors temperature sensor pressure sensor etc are processed by the electronic head which carries out specific operations based on the values it receives The CNG dispensers can be Single stage dispensers that control a single valve first stage level their hydraulic system communicates with one storage ta...

Page 8: ...the areas indicated with the arrows in this diagram areas are about 50 cm one from the other Always use the proper methods to lift and transport the dispenser Non compliance with the instructions for moving the dispenser could cause serious damages to things and people Once you have received the dispenser carefully inspect the equipment to ensure that it has not been damaged during transportation ...

Page 9: ...tem normally composed of an emergency button and one or more safety switches that is capable of interrupt the flow to the equipment in case of operating problems The emergency stopping system not included with the dispenser must comply with national regulations for example EN 60204 1 The safety device must be placed in the gas station in order that it is easily accessible to attendants Following a...

Page 10: ... Copyright 2008 03 20 V0 Rev 01 0 10 WT004139 ...

Page 11: ... Copyright 2008 03 20 V0 Rev 01 0 11 WT004139 ...

Page 12: ... Copyright 2008 03 20 V0 Rev 01 0 12 WT004139 ...

Page 13: ... Copyright 2008 03 20 V0 Rev 01 0 13 WT004139 ...

Page 14: ... Copyright 2008 03 20 V0 Rev 01 0 14 WT004139 ...

Page 15: ... Copyright 2008 03 20 V0 Rev 01 0 15 WT004139 ...

Page 16: ... by dispensing some gas following the procedure indicated in the following paragraph Check the meter s calibration by dispensing gas a few times and comparing the measurements given by the electronic head with those given by a proper sampling instrument For Example precision scale Dispensing procedure To dispense CNG follow these procedures remove the nozzle from its housing connect the nozzle to ...

Page 17: ... and electrical components External components 1 Lower front panel 2 Column 3 Nozzle Housing 4 Computing Head Housing 5 Cover 6 Base 7 Id plate Hydraulic components 8 Manual ball valve 9 Particulate filter 10 Check valve 11 Mass flow meter 12 Motorized valve 13 Pressure gauge 14 Delivery hose 15 Delivery Nozzle 16 Breakaway Device Electrical components 17 Electronic head 18 Pressure transmitter 19...

Page 18: ...he motorized valve includes a ball valve a solenoid and a pneumatic actuator When the dispensing selector is switched to the ON position dispensing the head sends a command to the solenoid which activates the inlet of compressed air into the actuator through the inlet door at this point the ball valve opens and the gas starts to flow The motorized valve returns to its initial position when the hea...

Page 19: ...damages to persons the dispenser and the vehicle ELECTRICAL COMPONENTS Electronic head Description The CNG dispenser is equipped with a Dresser electronic head which guarantees high performance in calculating and constantly monitoring all the operations carried out by the dispenser The head designed specifically to manage CNG dispensers performs the following operations management and control of t...

Page 20: ...NTENANCE The dispenser leaves the factory only after passing accurate tests hydraulic and electrical A correct installation and use should guarantee proper functioning In any case in order to maintain the dispenser s optimal conditions in time and guarantee its safety the station manager must check the components listed in the table below periodically Component Intervention Pneumatic actuator Peri...

Page 21: ... remember to disconnect the power supply before operating on the components of the CNG dispenser Cleaning To clean the dispenser do not use abrasive detergents or products petrol petroleum based products Instead use water with non aggressive detergents and soft cloths Adopt all necessary precautions to avoid any water entering the dispenser Before entering the head box carefully dry any traces of ...

Page 22: ...ens while the volume display will show the pre established unit price for example 1 235 0 1 235 1 235 For example pressing P0 once and P1 twice the display will appear as follows 2 1 235 Pressing P0 again another digit is added on the display and it can be increased or decreased by pressing P1 or P2 respectively 20 1 235 The same applies when setting the next digits If the new price is set the dat...

Page 23: ...an be set with the P001 parameter Values are 0 e 1 0 manual mode 1 automatic mode Warning if the dispenser is connected to the Host it will shift into automatic mode even if it is set to manual Further information For further information regarding programming operation and the meaning of certain error codes displayed by the electronic head refer to the related manual ...

Page 24: ... Year of construction 3 Type of product 4 Space for directions 5 II 3 G group II surface category 3 potentially explosive atmosphere due to presence of gas vapors or fog 6 CE marking in compliance with EMC and ATEX 7 Epsilon X marking in compliance with the ATEX directive 8 Name and address of the manufacturer 3 1 2 ID PLATE 4 5 6 7 8 ...

Page 25: ... Copyright 2008 03 20 V0 Rev 01 0 25 WT004139 DECLARATION OF CONFORMITY ...

Page 26: ...____________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ ___...

Page 27: ...V0 Rev 01 0 27 WT004139 MARKET SERVICE To obtain name and address of the closest authorized maintenance company please contact DRESSER WAYNE DRESSER Italia S r l Via Roma 32 23018 TALAMONA SO Tel 0342 608111 Fax 0342 608299 ...

Page 28: ...n with overall responsibility to the customer Field service technical support and supply of spare parts Ausrüstungen wie Zapfsäulen Zahlterminals Kassenterminals und Tankstellensysteme Software für Registrierung und Kommunikation auf der Tankstelle u zwischen Station und Mineralölfirma sowie Banken und Kreditinstituten Projektgestaltung mit umfassender Verantwortlichkeit dem Kunden gegenüber Servi...

Reviews: