Operating Instructions and Parts Manual

3

VIP Series

www.waynepumps.com

  This equipment is only for use on 120 volt 

(single-phase) and is equipped with an ap proved 3-conduc tor cord and 

3-prong, grounding-type plug.

1.  To reduce the risk of electric shock, the motor must be securely and 

adequately grounded. This can be ac com plished by inserting pump 
power cord plug directly into a properly installed and grounded 
3-prong  (GFCI),  ground ing-type  re cep ta cle.

 

Where a 2-prong wall receptacle is en coun tered, it must be re-
placed with a properly grounded 3-prong (GFCI) re cep ta cle installed 
in accordance with the NEC and local codes and ordinances.

2.  Protect electrical cord from sharp ob jects, hot sur fac es, oil, and 

chemicals. Do not operate with damaged cord.

3.  Do not handle a pump or pump motor with wet hands or when 

standing on a wet or damp surface, or in water.

  If your basement or room has water or moisture 

on the floor, do NOT walk on wet area until all power has been turned 

off. If the shut-off box is in the basement, call the electric company 

to shut-off service to the house, or call your local fire department for 

instruction. Failure to follow this warning WILL result in fatal electrical 

shock.

  Si le sous-sol ou la pièce a de l’eau ou de 

l’humidité sur le plancher, ne PAS marcher aux endroits mouillés 

avant que le courant ne soit coupé. Si le boîtier de coupure de courant 

se trouve au sous-sol, appeler la société d’électricité pour couper le 

courant de la maison, ou encore appeler le service d’incendie local pour 

des instructions. Le non-respect de cet avertissement ENTRAÎNERA un 

choc électrique mortel.

GENERAL SAFETY INFORMATION (CONT’D)

  Disconnect power before servicing. If the power 

disconnect is out of sight, lock in the open (OFF) position and tag it to 

prevent unexpected application of power. Failure to do so COULD result 

in fatal electrical shock!

  Débrancher l’alimentation avant de procéder 

à l’entretien. Si la source de courant n’est pas visible, verrouiller en 

position ouverte (OFF) et étiqueter pour éviter tout rétablissement 

inattendu de l’électricité. Ne pas suivre ces instructions POURRAIT 

mener à une décharge électrique mortelle.

4.  Release all pressure within the system before ser vic ing any 

component.

5.  Drain all liquids from the system before servicing.
6.  Secure the discharge line before starting the pump. An unsecured 

discharge line will whip, possibly caus ing personal injury and/or 
property damage.

7.  Check hoses for weak and worn condition before each use, making 

certain that all connections are secure, and open ended.

8.  Periodically inspect the pump and system com po nents. Perform 

routine maintenance as required (See Main te nance Section, on 
page 3).

   This pump is not designed to handle salt water, 

brine, laundry discharge, water softner, sewage, grey water, or any 

other application which may contain caustic chemicals and/or foreign 

materials. Pump and/or property damage could occur if used in these 

applications and will void warranty.

Personal Safety

a.  Wear safety glasses at all times when working with pumps.
b.  Keep work area clean, uncluttered and prop er ly light ed; replace 

all unused tools and equipment.

c.  Keep visitors at a safe distance from the work area.

  When using an electrically driven pump such 

as this, follow all electrical and safety codes, as well as the most recent 

National Electrical Code (NEC) and the Occupational Safety and Health 

Act (OSHA). All wiring should be performed by a qualified electrician.

  En utilisant une pompe électrique comme 

celle-ci, respecter tous les codes de sécurité et d’électricité en plus du 

Code national de l’électricité (CNE) le plus récent et aux États-Unis, la 

loi Occupational Safety and Health Administration Act (OSHA). Tout le 

câblage doit être effectué par un électricien qualifié. 

Summary of Contents for VIP50

Page 1: ...ose Threads Submersible Multi Use Pumps www waynepumps com PERFORMANCE Model HP Discharge Head 0 ft 5 ft 10 ft 15 ft 20 ft VIP50 1 2 Gal hr 2600 2160 1680 1080 300 VIP15 1 5 Gal hr 2050 1740 1350 880...

Page 2: ...multi use pump is designed and in tend ed for non automatic use in water The units are equipped with an 8 ft 3 prong ground ing type power cord The motor is oil filled and sealed for cooler running a...

Page 3: ...event unexpected application of power Failure to do so COULD result in fatal electrical shock D brancher l alimentation avant de proc der l entretien Si la source de courant n est pas visible verrouil...

Page 4: ...ebout dans l eau ou sur une surface humide Ne JAMAIS toucher la pompe ou la tuyauterie d vacuation lorsque l unit fonctionne ou ne fonctionne pas correctement TOUJOURS d brancher le cordon d alimentat...

Page 5: ...s concessionnaires ou des lectriciens qualifi s peuvent essayer de r parer cet appareil Une r paration inad quate POURRAIT provoquer un risque de choc lectrique 1 No oiling is required for this pump T...

Page 6: ...ture 2 Pump has run dry or insufficient fluid level for pump to prime 3 Low supply voltage 1 Pump should not be used in water above 120 2 Reposition pump in adequate water pump uses water for cooling...

Page 7: ...IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE W...

Page 8: ...www waynepumps com 8 NOTES...

Reviews: