OPERATION (CONT’D)
A pump that has a tripped thermal protector
may start suddenly!
Une pompe dotée d’un protecteur thermique
activé peut démarrer soudainement!
2. The pump will pump water down to 1/4 in., therefore the pump will
not remove all of the water. Shut off the pump immediately if the
unit has been operating and suddenly no water comes out of the
discharge hose. The water level is probably very low and the pump
has broken prime. Use a mop or squeegee to remove the remaining
water.
MAINTENANCE
Make certain that the pump is unplugged
before attempting to service or remove any component. This pump
is assembled in the factory using special equipment; therefore only
authorized service dealers or qualified electricians should attempt
to repair this unit. Improper repair COULD cause an electrical shock
hazard.
Toujours s’assurer que la pompe est
débranchée avant de procéder à un entretien, une réparation ou de
retirer tous composants. Cette pompe est assemblée en usine utilisant
de l’équipement spécial, par conséquent seuls des concessionnaires
ou des électriciens qualifiés peuvent essayer de réparer cet appareil.
Une réparation inadéquate POURRAIT provoquer un risque de choc
électrique.
1. No oiling is required for this pump.
The pump contains oil that may be under
pressure because of heat. Let the pump cool for a minimum of two
hours before servicing this unit.
La pompe contient de l’huile qui pourrait
être sous pression en raison de la chaleur. Laisser la pompe refroidir
pendant au moins deux heures avant tout entretien ou réparation de cet
appareil.
Disassembly of the motor prior to expiration
of warranty will void the warranty. It might also cause internal leakage
and damage to the unit. If repairs are re quired, return the pump to the
dealer from whom it was purchased or contact local electrical repair
shop station.
2. Inlet should be kept clean and free of all foreign objects and debris.
This pump contains dielectrical motor oil for
lubrication and motor heat transfer. This oil CAN be harmful to the
environment. Check the state environmental laws before disposing of
this oil.
Cette pompe contient de l’huile à moteur
diélectrique pour la lubrification et le transfert de chaleur du moteur.
Cette huile PEUT être dangereuse pour l’environnement. Vérifier les lois
environnementales de l’État avant de la mettre au rebut.