Auto On-Off Water Removal 

Pool Cover Pump

OPERATING INSTRUCTIONS & PARTS MANUAL

READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL - DO NOT DISCARD.  

Failure to follow these instructions could result in property damage, serious injury or death.

 

Risk of electric shock. This pump  

 has 

NOT been tested for use in marine 

areas. NEVER place pump in pools while people are in the water. 

Do NOT handle pump with wet hands or when standing in water 

or on a damp surface. Pump is designed to be used in closed and 

covered pools  only. Water accumulated on pool cover can cause 

injury or death. Proper installation of pool cover pump and periodic 

maintenance is recommended. Failure to follow COULD result in 

death or serious injury.

1.   Wear safety glasses at all times when working       

 

with pumps.

2.   The unit MUST be plugged into a properly 

grounded GFCI outlet. Consult with a qualified 

electrician for proper installation of a GFCI OUTLET.

3.   DO NOT MOVE, POSITION, RETRIEVE, OR CARRY PUMP 

USING THE POWER CORD OR THE DISHCHARGE HOSE, 

damage to the pump or power cord may occur. Use the 

handle supplied on the pump or attach a string to the strainer 

to position as instructed. 

APPLICATION AND OPERATION

  

Do NOT use pump if any part of the housing 

  switch or probe is cracked, broken, or missing.

 

Always disconnect      

  electric supply 

before attempting to install, service, 

relocate, or perform any maintenance. If 

the power source is out of sight, lock and 

tag in open (off) position to prevent unexpected power application. 

Failure to do so WILL result in fatal electrical shock!

 

Electric shock hazard. Use only      

  Underwriters Laboratories 

(UL)- listed extension cord with #16 gauge or larger wire 

that is labeled for outdoor use. Use polarized grounding 

type plugs only. Polarized plugs have one blade slightly 

wider than the other and can only be inserted one way into the 

outlet. If using an extension cord, do NOT allow pump cord/

extension cord connection to fall into swimming pool or come in 

contact with water. Pump/extension cord connection must be kept 

dry and away from moisture. Do NOT handle plug connector near 

water. Failure to follow these instructions WILL result in death or 

serious injury.

  

This unit is NOT designed for use    

 as a sump pump or in sump 

applications. This unit is NOT designed for use in septic 

tanks or underground vaults to pump raw sewage or 

effluents. NEVER use in hazardous or explosive locations.

DESCRIPTION

This portable, Auto On-Off Pool Cover pump is designed for 

automatic removal of water, from a pool or spa cover. The units 

are equipped with a 25 ft. 3-prong grounding type power cord. 

The provided discharge check valve prevents short cycling and 

it's 3/4 in adapter can be used for convenient attachment to a 

standard garden hose.

UNPACKING

Inspect this unit before it is used. Occasionally, products are 

damaged during shipment. If the pump or components are 

damaged, contact customer service at 1-800-237-0987.

SAFETY GUIDELINES

To help recognize this information, observe the following signal 

words/hazard classifications. 

 

This is the safety alert symbol. It is used to alert you to  

 

 

potential bodily injury hazards. Obey all safety messages that  

 

follow this symbol to avoid possible harm.

 

Danger indicates an imminently hazardous 

  situation which, if NOT avoided, WILL result  

 

in death or serious injury.

 

Warning indicates a potentially hazardous 

  situation which, if NOT avoided, COULD  

 

 

result in death or serious injury.

 

Caution indicates a potentially hazardous 

  situation which, if NOT avoided, MAY result   

 

in minor or moderate injury.

 

Notice indicates important information, that if 

  NOT followed, MAY cause damage to equipment.

 

NOTE

: Note indicates information that requires special attention.

GENERAL SAFETY INFORMATION

GENERAL SAFETY
•    Read the manual(s) included with this product          

 

carefully. Be thoroughly familiar with the controls 

and the proper use of the equipment. Follow all 

instructions.

•    Only persons well acquainted with these rules of safe 

operation should be allowed to use the unit. Keep away 

    from children!

 

This pump is NOT rated for use  

 

with flammable/combustible 

liquids vapors or dusts. Do NOT use to pump flammable/

combustible liquids vapors or dusts. Do NOT use in a 

flammable and/or explosive atmosphere. Pump SHOULD 

be used to pump clear water ONLY. Failure to follow these 

instructions WILL result in bodily injury or death.
 

Electric shock hazard! GFCI  

   receptacles will provide protection 

against line to ground faults only. The ground fault 

receptacle does NOT limit the magnitude of fault current 

and will NOT prevent an electrical shock. Replace damaged cord 

immediately.

© 2012,  
WAYNE/Scott Fetzer Company.

 

Do NOT disassemble or alter this  

  product in any way. Failure to 

follow these instructions WILL result in serious injury or 

death.

2

Summary of Contents for WAPC250

Page 1: ...4 12 1 POOL COVER PUMP 1 PUMP STRAINER STEP 1 VERIFY PACKAGE CONTENTS STEP 2 INSTALL CHECK VALVE STEP 3 ATTACH STRAINER STEP 4 CONNECT GARDEN HOSE STEP 5 SECURE ROPE TO STRAINER STEP 6 POSITION ON POO...

Page 2: ...is NOT designed for use as a sump pump or in sump applications This unit is NOT designed for use in septic tanks or underground vaults to pump raw sewage or effluents NEVER use in hazardous or explos...

Page 3: ...cover before placing the pump For further placement techniques see Figures A E PULL ACROSS PUMP INSTALLATION To aid in pump placement on pool cover secure provided 25 ft rope to the pull to shore loo...

Page 4: ...n its side or inverted The shaft seal depends on water for lubrication allowing the pump to remain in any other orientation than upright could cause shaft seal failure or pump failure Pump starts auto...

Page 5: ...for a period of time to attempt to free the impeller until eventually the unit will remain off for a period of 12 hours checking twice a day for a freed impeller Once the pump is able to operate corre...

Page 6: ...ou specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort in clud ing negligence or otherwise...

Page 7: ...Notes 7 WAPC250 www waynepumps com...

Page 8: ...CLAPET DE NON RETOUR TAPE 3 FIXATION DU FILTRE TAPE 4 RACCORDEMENT DU TUYAU D ARROSAGE TAPE 5 FIXATION DE LA CORDE AU FILTRE TAPE 6 POSITIONNEMENT SUR LA COUVERTURE DE LA PISCINE TAPE 7 BRANCHEMENT D...