background image

SYSTEM DESCRIPTION

This product is fully assembled and pre-plumbed 1/2 HP primary &  
12 Volt backup sump system. The pumps are designed for use in 
residential basements to remove groundwater and prevent flooding. 
The pumps are designed for clear water only. LED indicator lights 
inform the howeowner of the charge status of the battery. Wayne 
recommends the WSB1275, 75 AMP hr maintenance free battery 
(sold seperately), to complete the sytem. Designed for 15 in. diameter 
or larger sump basins. This system is intended for indoor use only.
Installation of this pump outdoors, unprotected from the weather, 
may cause hazardous conditions and will void warranty. If using 
outdoors, protect pump from direct weather elements such 
as sun, rain, sleet, snow, and extreme temperature changes. 
Water inside the pump may freeze, limiting its performance and 
damaging the pump and pipes.

UNPACKING

Inspect this unit before it is used. Occasionally, products are damaged 
during shipment. If the pump or components are damaged, return 
the unit to the place of purchase for replacement, or call Customer 
Support (800-237-0987).

SAFETY SIGNAL WORDS 

This manual contains information that is very important to know and 
understand. This information is provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS. To help recognize this information, observe 
the following symbols.

  Danger indicates an imminently hazardous 

situation which, if NOT avoided, WILL result in death or serious injury.

  La mentio ger indique une situation dangereuse 

imminente qui, si elle n’est pas évitée, ENTRAÎNE la mort ou des blessures 

graves.

  Warning indicates a potentially hazardous situation 

which, if NOT avoided, COULD result in death or serious injury.

  La mention avertissement indique une situation 

potentiellement dangereuse qui, si elle n’est pas évitée, risque d’entraîner 

des lésions corporelles graves ou même la mort.

   Caution indicates a potentially hazardous situation 

which, if NOT avoided, MAY result in minor or moderate injury.

 MISE EN GARDE

   La mention mise en garde indique une 

situation potentiellement dangereuse qui, si elle n’est pas évitée, pourrait 

entraîner des blessures mineures ou modérées.

  Notice indicates important information, that if NOT 

followed, MAY cause damage to equipment.

IMPORTANT SAFETY INFORMATION

RISK OF ELECTRIC SHOCK. TO REDUCE THIS RISK, 

OBSERVE THE FOLLOWING WARNINGS:
RISQUE DE CHOC ÉLECTRIQUE. POUR RÉDUIRE CE RISQUE, 

TENIR COMPTE DES AVERTISSEMENTS SUIVANTS :

MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE 

AVAILABLE.  

The AC pump & transformer are supplied with a 

grounding conductor and grounding-type attachment plug. To 

reduce the risk of electric shock, be certain that it is connected 

only to a properly grounded, grounding-type receptacle.

S’ASSURER QU’UNE PRISE DE MISE À LA TERRE EST DISPONIBLE. 

Cette 

pompe et le transformateur c.a. sont fournis avec un conducteur 

et une fiche de type mise à la terre. Pour réduire le risque de choc 

électrique, s’assurer qu’elle est branchée seulement à une prise de 

courant correctement mise à la terre.

FOR ADDED SAFETY 

the receptacle must be protected with a ground 

fault circuit interrupter (GFCI). All wiring must be performed by a 

qualified licensed electrician and comply with the National Electric 

Code and all applicable local codes and ordinances.

POUR PLUS DE SÉCURITÉ, 

la prise de courant doit être protégée par 

un disjoncteur de fuite à la terre. Tout le câblage doit être effectué 

par un électricien qualifié et être conforme au Code électrique 

national et à tous les codes et règlements locaux applicables.

NEVER REMOVE THE GROUND PRONG 

from the plug or bypass the 

grounding wires.

NE JAMAIS RETIRER LE CONNECTEUR DE MISE À LA TERRE 

de la prise 

ou contourner les fils de mise à la terre.

THIS SYSTEM IS NOT DESIGNED TO HANDLE SALT WATER, 

BRINE, LAUNDRY DISCHARGE, WATER SOFTENER, SEWAGE, 

GREY WATER, OR ANY OTHER APPLICATION WHICH MAY 

CONTAIN CAUSTIC CHEMICALS AND/OR FOREIGN MATERIALS. 

PUMP AND/OR PROPERTY DAMAGE COULD OCCUR IF USED IN 

THESE APPLICATIONS AND WILL VOID WARRANTY

DO NOT REMOVE POWER SUPPLY CORD 

and strain relief or connect 

conduit directly to the pump.

NE PAS RETIRER LE CORDON D’ALIMENTATION ÉLECTRIQUE 

et le 

réducteur de tension, ni connecter le conduit directement à la 

pompe.

MAKE SURE THE POWER SUPPLY HAS A FUSE OR CIRCUIT BREAKER 

rated to handle the current (amps) noted on the pump nameplate 

or cord tag.

S’ASSURER QUE L’ALIMENTATION ÉLECTRIQUE EST MUNIE D’UN 

FUSIBLE OU D’UN DISJONCTEUR 

d’une valeur nominale appropriée 

pour supporter l’intensité du courant (ampérage) indiquée sur la 

plaque signalétique ou l’étiquette du cordon de la pompe.

2

www.waynepumps.com

Operating Instructions and Parts Manual

Summary of Contents for WSS30Vn

Page 1: ...c SHAFT Steel Stainless Steel DISCHARGE 1 1 2 in NPT Submersible Sump Pump System www waynepumps com Intended for Indoor Use Only Please read and save these instructions Read carefully before attempti...

Page 2: ...cause damage to equipment IMPORTANT SAFETY INFORMATION RISK OF ELECTRIC SHOCK TO REDUCE THIS RISK OBSERVE THE FOLLOWING WARNINGS RISQUE DE CHOC LECTRIQUE POUR R DUIRE CE RISQUE TENIR COMPTE DES AVERT...

Page 3: ...CORD OR SURGE PROTECTOR Extension cords and or surge protectors could present a safety hazard if not sized properly become damaged or the connection falls into the sump If receptacle is not within rea...

Page 4: ...and water Si de l acide de batterie entre en contact avec les yeux les rincer avec de l eau courante froide pendant 10 minutes et consulter imm diatement un m decin Si l acide entre en contact avec l...

Page 5: ...and is free to move throughout its travel 7 Install discharge plumbing according to local regional and state codes Rigid PVC pipe is required Do not use flexible hose in a permanent application A 1 1...

Page 6: ...onnectors The connections are all unique and cannot be interchanged FLOOR JOIST RIGID PVC PIPE TRANSFORMER REQUIRED CHECK VALVE SEE STEP 3 7 BATTERY BOX PRIMARY AC PUMP BACKUP DC PUMP SLOPE PIPE DOWN...

Page 7: ...tery voltage particularly with a defective battery In order for the indicator light to provide an accurate reading steps a through d must be followed Risk of electrical shock Unplug main ac pump and t...

Page 8: ...incorrect motor conditions or at the end of its life AC ROUTINE SUMP MAINTENANCE The pump system should be inspected 3 4 times per year for movement or buildup of debris on the switch or float Reposi...

Page 9: ...ion to ensure free motion of switch 4 Remove obstruction in discharge piping 5 Contact an electrician Pump operates noisily or vibrates excessively 1 Worn bearings 2 Impeller broken 3 Piping attachmen...

Page 10: ...e as needed 3 Make sure nothing is interfering with operation of switch 4 Pull the transformer from the wall outlet and remove Check the 20 Amp Automotive Sytle fuse located under the battery box lid...

Page 11: ...e Harrison OH 45030 U S A REPAIR KITS MODEL ALL MODELS REF NO DESCRIPTION PART NUMBER 1 FLOAT KIT 60038 WYN1 2 TRANSFORMER 60194 WYN1 3 BACK UP SWITCH Call for part 4 LID ASSEMBLY 60184 WYN1 4 2 1 3 1...

Page 12: ...SALE OF THE PRODUCT THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING WITH RESPECT TO OR IN ANY...