TROUBLESHOOTING WARNINGS

LET PUMP COOL FOR A MINIMUM OF 2 HOURS BEFORE 

ATTEMPTING TO SERVICE. 

Submersible pumps contain oil that 

become pressurized and hot under normal operating conditions.

LAISSER REFROIDIR LA POMPE PENDANT AU MOINS 2 HEURES 

AVANT D’ESSAYER DE LA RÉPARER. 

Les pompes submersibles 

contiennent de l’huile qui devient pressurisée et chaude dans des 
conditions normales de fonctionnement.

1.  Submersible pump models have permanently lubricated 

bearings and require no additional lubrication.

2.  Submersible pump contains dielectric oil for cooling.  

Dielectric oil can be harmful to the environment.  Follow 
state environmental laws when disposing of pump.

3.  The AC pump motor is equipped with automatic resetting 

thermal protector and may restart unexpectedly.  Protector 
tripping is an indication of motor overloading as a result of 
operating the pump at low heads, excessively high or low 
voltage, inadequate wiring, incorrect motor conditions, or at 
the end of its life.

AC ROUTINE SUMP MAINTENANCE

The pump system should be inspected 3-4 times per year for 
movement or buildup of debris on the switch or float. Reposi-
tion system if it has moved. Remove any debris that could 
interfere with the operation of the switches. Lack of proper 
routine maintenance will void warranty.

• Make sure the system is plugged in to a working ground fault 
circuit interrupter (GFCI) outlet and the cord is in good shape. 
In damp areas, GFCI breakers may trip, effectively shutting off 
the sump pump. Check in on your sump pump and reset the 
GFCI if necessary. Replace pump if GFCI continues to trip.

• Ensure the system is upright. Vibrations during operation can 
cause it to fall or tilt onto one side. This can jam the float so it 
can’t activate the pump.

• Pour a bucket of water into the pit to make sure the AC 
pump starts automatically and the water drains quickly once 
the pump is on. If the pump doesn’t start, have it serviced or 
replaced.

• Check the inlet screen and clear away any small stones or 
debris.

8

www.waynepumps.com

Operating Instructions and Parts Manual

Summary of Contents for WSS30Vn

Page 1: ...c SHAFT Steel Stainless Steel DISCHARGE 1 1 2 in NPT Submersible Sump Pump System www waynepumps com Intended for Indoor Use Only Please read and save these instructions Read carefully before attempti...

Page 2: ...cause damage to equipment IMPORTANT SAFETY INFORMATION RISK OF ELECTRIC SHOCK TO REDUCE THIS RISK OBSERVE THE FOLLOWING WARNINGS RISQUE DE CHOC LECTRIQUE POUR R DUIRE CE RISQUE TENIR COMPTE DES AVERT...

Page 3: ...CORD OR SURGE PROTECTOR Extension cords and or surge protectors could present a safety hazard if not sized properly become damaged or the connection falls into the sump If receptacle is not within rea...

Page 4: ...and water Si de l acide de batterie entre en contact avec les yeux les rincer avec de l eau courante froide pendant 10 minutes et consulter imm diatement un m decin Si l acide entre en contact avec l...

Page 5: ...and is free to move throughout its travel 7 Install discharge plumbing according to local regional and state codes Rigid PVC pipe is required Do not use flexible hose in a permanent application A 1 1...

Page 6: ...onnectors The connections are all unique and cannot be interchanged FLOOR JOIST RIGID PVC PIPE TRANSFORMER REQUIRED CHECK VALVE SEE STEP 3 7 BATTERY BOX PRIMARY AC PUMP BACKUP DC PUMP SLOPE PIPE DOWN...

Page 7: ...tery voltage particularly with a defective battery In order for the indicator light to provide an accurate reading steps a through d must be followed Risk of electrical shock Unplug main ac pump and t...

Page 8: ...incorrect motor conditions or at the end of its life AC ROUTINE SUMP MAINTENANCE The pump system should be inspected 3 4 times per year for movement or buildup of debris on the switch or float Reposi...

Page 9: ...ion to ensure free motion of switch 4 Remove obstruction in discharge piping 5 Contact an electrician Pump operates noisily or vibrates excessively 1 Worn bearings 2 Impeller broken 3 Piping attachmen...

Page 10: ...e as needed 3 Make sure nothing is interfering with operation of switch 4 Pull the transformer from the wall outlet and remove Check the 20 Amp Automotive Sytle fuse located under the battery box lid...

Page 11: ...e Harrison OH 45030 U S A REPAIR KITS MODEL ALL MODELS REF NO DESCRIPTION PART NUMBER 1 FLOAT KIT 60038 WYN1 2 TRANSFORMER 60194 WYN1 3 BACK UP SWITCH Call for part 4 LID ASSEMBLY 60184 WYN1 4 2 1 3 1...

Page 12: ...SALE OF THE PRODUCT THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING WITH RESPECT TO OR IN ANY...

Reviews: