MF Freezer
Operating manual
WCB Ice Cream
17-29
Pump Parameters
By pre-selecting the Pump Field on the Main Set-up Menu and pressing K10 (Enter) you will get into
the first of the adjustable Pump Parameters.
Pump Calibration Min Capacity
On this screen you set the pump capacity in litres per hour when the pumps are running at minimum
speed.
As the pump rotors wear down you may have to adjust this value in order to obtain a correct mix flow
read out.
By pressing K7 (Arrow) up you increase the parameter and by pressing K8 (Arrow Down) you
decrease the parameter. Keeping the keys pressed will make the adjustments go faster and faster.
The parameter adjustment is immediately being stored. There is no need for acknowledging the
adjustment.
If you press K5 (Escape) you will return to the Main Set-up Menu. By pressing K10 (Enter) you will go
to the next adjustable Pump Parameter:
Pump Calibration Max Capacity
On this screen you set the pump capacity in litres per hour when the pumps are running at maximum
speed.
As the pump rotors wear down you may have to adjust this value in order to obtain a correct mix flow
read out.
By pressing K7 (Arrow) up you increase the parameter and by pressing K8 (Arrow Down) you
decrease the parameter. Keeping the keys pressed will make the adjustments go faster and faster.
The parameter adjustment is immediately being stored. There is no need for acknowledging the
adjustment.
If you press K5 (Escape) you will return to Pump Calibration Min Capacity. K10 (Enter) will not work
since the Pump Calibration Max Capacity is the last parameter in this sub menu.