37
ELECTRICAL INSTALLATION
• Electrical connection should be made via its own dedicated supply
• Install a suitable conduit/pipe to carry all wires from the kiosk and high-
level alarm float switch
• Run a draw line through the conduit/pipe
• Tie the draw line to the cables and pull the cables through the fittings, into
the conduit/pipe and through to the blower kiosk
• Connect the float switch (for the high-level alarm) to the junction box
• Plug the flying lead from the red beacon into the junction box
• Connect the mains supply from an RCD protected power supply and turn on
• Image below shows the wiring layout inside the junction box
Chamber:
• Ensure that the pump is fully engaged with auto coupling
• Inspect all connections for leaks
BLOWER
RED BEACON
MAINS 220V
PUMP
S (BLACK)
L (BROWN)
B (BLUE)
FLOAT SWITCH
FLOAT
L B S
S N
BEACON
L N E
PUMP
BLOWER
L N E
MAINS
E L N