  We all know that the relay is a certain life, the relay inside 

the metal reed will be damaged, then need to rely on 

professionals to repair replacement, not only the high cost 

and more disputes. 

The new design of the S5645 to complete the maintenance 

and replacement to overcome the problem, each relay 

device is easy to replace the modular structure, the 

efficient future maintenance, to avoid the maintenance 

process of the many problems. 

The new design of the 5645S also confused the previous 

engineering staff to solve the actual lighting feedback 

problems, with current sensing components RL-PB01 can 

accurately and efficiently identify the actual light switch 

status, "WYSIWYG" has been the system operator Efforts 

to implement the objectives, using 5645S will make your 

project planning more perfect!

 

Easy To 
Replacement 

Introduction 

Summary of Contents for LIGHT LINK EZ-5645S

Page 1: ...sign of the S5645 to complete the maintenance and replacement to overcome the problem each relay device is easy to replace the modular structure the efficient future maintenance to avoid the maintenance process of the many problems The new design of the 5645S also confused the previous engineering staff to solve the actual lighting feedback problems with current sensing components RL PB01 can accu...

Page 2: ...nstall the unit in a wet location and there is a danger of electric shock Please follow the instructions to fix the machine to avoid loose shaking After installation check whether the wiring is correct before turning on the power Strictly prohibit any disassembly modification demolition or modification shall be deemed to give up the machine warranty interest When the machine fails please contact t...

Page 3: ...485 can be connected to any standard protocol system host Software or hardware can set the ID easy to implement multi machine control With 6 groups of independent IO can be connected to the general wall switch panel the system host executable control With a total set of IO contacts can be set according to demand the implementation of the loop With serial output function can be expanded to 12 loops...

Page 4: ...DC12V 2A above Control voltage AC 110 220V Maximum load Single loop 20A B connected to load A not connected to wall switch Single loop 10A B connected to load A connected to wall switch The above load should be added instantaneous current Current consumption standby current 70mA operating current 450mA Packing environmental carton Safety regulations CE FCC DC12V Input Total DI Single DI 6 Indicato...

Page 5: ...ocument may be reproduced by any means without written permission of the copyright owner http www wdh com tw 5 10 RL PB01 Relay with detection module 6 2 PIN Terminal blocks 9 4 PIN Terminal blocks 1 Removable fixed iron 2 Fixing screws 4 Optional accessories standard aluminum rail clip AE 005 B A Accessories ...

Page 6: ...permission of the copyright owner http www wdh com tw 6 10 Installation location Note Ventilation is good not moisture to avoid the location of children to touch Do not touch Unless you turn off the power to avoid electric shock 1 2 4 3 Follow the steps below to remove the fixed iron plate at the bottom of the 5645S and attach it to fix the machine Installed Fixed ...

Page 7: ...General lighting switch circuit installation wiring through the command of the 5645S control action Each RL PB01 is planned A B double contact The middle point for the input B contact load current higher than the A contact 5645S only control the load 3W of light or power equipment And can not be used as a dry contact switch controller Electric load configuration Control load requirements Master Sl...

Page 8: ...ut switch or Bell switch According to the configuration of different switch types 5645S contact mode can be set by command General switch General switch Double cut switch configuration The use of wall double cut switch and 5645S integrated into a true double cut switch or even 5645S failure Wall switch can also be normal control of light power Regardless of the state of the wall switch is on or of...

Page 9: ...any means without written permission of the copyright owner http www wdh com tw 9 10 5645S relay is a modular detachable structure fault replacement please follow the instructions RL PB01 relay modular Press here Push the module forward Up Remove RL PB01 RL PB01 Do not touch the gold plated metal contact with your hand Remove replacement ...

Page 10: ...y any means without written permission of the copyright owner http www wdh com tw 10 10 EZ 5645S LED specific dimmer Tungsten TRICK dimmer Can constitute a multi loop light control system EZ 5645S Six loops switch controller EZ L816F Six output LED dimmer EZ D496F Four loop tungsten light dimmer Complete lighting power control solution ...

Reviews: