5.  

Technical Data 

 
The dosing unit DUFTDOS UNPL SA with surface sensor consists of: 

-

 

peristaltic dosing pump type Sa 

-

 

special hose from Viton 

-

 

Controller UNPL-temperature with dosing-pause-adjustment 

-

 

Dosing rate 1ml to 5ml each dosing 

-

 

Hose-surface sensor  

-

 

Suction hose from PE 4x1mm; 1,5m long 

 

Options 
Title

 

 

 

 

 

 

 

article number 

Dosing–set DD complete: 

 

 

 

 

12596 

-

 

Dosing valve for fragrance SS 3/8”    

 

15108 

-

 

3m dosing hose PTFE 6/4x1mm 

 

 

10432 

Console with 1,5l canister 

 

 

 

 

13892 

Console PE gray for 3-10l canister 

 

 

 

14391 

Piezo push button 24V, diameter 60mm   

 

 

23561 

Mounting sleeve for LED spots d-55mm/l-113mm 

 

 

20924 

Sealing flange, tiles d48mm complete 

 

 

 

20976-1 

 

 

6.  

Fragrance pump 

 

A peristaltic dosing pump is used for dosing, which safely promotes also smallest quantities. Even 

when Air- or gas-bubbles are trapped in the suction line. Rotating rolls press the dosing hose 

against the pump tube housing, whereby the liquid within the hose is pressed out in front of the 

rolls and at the same time drawn in behind them. The pump is extremely reliable and very 
simple to handle. 

 

Fragrance  concentrates  are  very  aggressive.  The  used  dosing  hose  is  resistant  against  most 

concentrates that are in common use in the industry but we still recommend to check with your 

equipment supplier prior to use.  

 

 

Attention!  

-

 

Back pressure must not be higher than 0.5 bar  

-

 

Use only original WDT dosing valves. 

-

 

Don´t bend the dosing tube. 

-

 

Use only PTFE dosing tube. 

 

Company WDT can take no warranty for the resistance of the hose against every fragrance concentrate on the 

market! 

Summary of Contents for Duftdos UNPL

Page 1: ...bols 2 2 Saftey 3 2 1 Technical safety advice 3 2 2 Use in accordance with regulations 4 3 Delivery 4 4 Function 4 5 Technical Data 5 6 Fragrance pump 5 6 1 Change the hose set 6 6 2 Sparepartlist per...

Page 2: ...essible at all times 1 4 Further informations For further information please contact your dealer or company WDT Werner Dosiertechnik GmbH Co KG 1 5 Used symbols Danger Warning of Danger Failure to obs...

Page 3: ...y After any repair work have qualified personnel check the safe operation of the unit Use original spare parts only Additional national safety regulations also fully apply to the operation of this uni...

Page 4: ...After you press the push button the dosing is activated for 0 5 seconds till 5 seconds adjustable and aroma is injected into the steam pipe Afterwards the dosing is locked for an adjustable 1 20 minu...

Page 5: ...6 Fragrance pump A peristaltic dosing pump is used for dosing which safely promotes also smallest quantities Even when Air or gas bubbles are trapped in the suction line Rotating rolls press the dosi...

Page 6: ...t persitaltic pump frangrance The peristaltic pump article no Transparent pump cover Sa 14259 Safety disc for roller Sa blue 13633 Hose holder Sa for fragrance with Viton hose 13358 Hose set Sa 2 dosi...

Page 7: ...ommissioning Dosing The dosing unit has to be mounted in an easily accessible place on the wall about 1m above the floor The fragrance canister is placed under the unit The suction hose is inserted in...

Page 8: ...sensor head Then you adjust the desired dosing value at the rotary knob for the dosage The dosing pump delivers per second running time approximately 1 ml fragrance The green LED indicates the unit i...

Page 9: ...suring points is 730 ohms If the switch on temperature should be changed so you can do these when you turn the adjustment screw at the potentiometer If you turn clockwise the switch on temperature wil...

Reviews: