Operation manual 20997-Duftdos-UNPL (09/16)
Page 6 von 9
6.1
Change the hose set
Remove the transparent pump cover and the blue safety disk. To change the hose set the hose holder, suction and pressure connections have
to be pulled forward. Turn the roller to the clockwise and pull out the pump hose over the cut-out at the roller. On reassembly reverse this
process.
6.2
Sparepartlist persitaltic pump frangrance
The peristaltic pump
article no.
Transparent pump cover Sa
14259
Safety disc for roller Sa blue
13633
Hose holder Sa, for fragrance with Viton hose
13358
Hose set Sa (2 dosing hose 3,2x1,6 Viton Sa, with 4 hose clips)
12782
Roller yellow
12609
Pump housing blue
14140
Felt grommet
14166
Membrane
12709
Gear motor
18769
Mounting screws
17067
Electrical connection red = positive / black = negative 24VDC
Housing
Safety disc
Roller
Hose holder with connections
Suction side
Pressure side
Attention
The hose must not be inserted
twisted.
Please observe the marks!