Change the hose set 

 
Remove the transparent pump cover and the blue safety disk. To change the hose set the hose holder, suction and pressure connections have 

to be pulled forward. Turn the roller to the clockwise and pull out the pump hose over the cut-out at the roller. On reassembly reverse this 

process.  

 

 

 

 

 

 

 

 

 

 

 

6.2  

Sparepartlist persitaltic pump frangrance  

 

 

 

 

 

 
 

 
 

 

 

 

 

 

 

 

 

 
 

 
 

 

 

 

 

 

The peristaltic pump   

 

 

 

article no. 

 

Transparent pump cover Sa 

 

 

 

 

14259 

Safety disc for roller Sa blue 

 

 

 

 

13633 

 
 

Hose holder Sa, for fragrance with Viton hose 

 

 

13358 

Hose set Sa (2 dosing hose 3,2x1,6 Viton Sa, with 4 hose clips)   

12782 

Roller yellow 

 

 

 

 

 

12609 

 

 

Pump housing blue   

 

 

 

 

14140 

Felt grommet 

 

 

 

 

 

14166 

Membrane  

 

 

 

 

 

12709 

 
Gear motor 

 

 

 

 

 

18769 

 

Mounting screws 

 

 

 

 

 

17067 

 

Electrical connection red = positive / black = negative 24VDC 

 

 

Housing 

 

Safety disc 

 

Roller 

 

Hose holder with connections 

 
Suction side 

 
Pressure side 

Attention 

 

The hose must not be inserted 
twisted.  
 
Please observe the marks! 

Summary of Contents for Duftdos UNPL

Page 1: ...bols 2 2 Saftey 3 2 1 Technical safety advice 3 2 2 Use in accordance with regulations 4 3 Delivery 4 4 Function 4 5 Technical Data 5 6 Fragrance pump 5 6 1 Change the hose set 6 6 2 Sparepartlist per...

Page 2: ...essible at all times 1 4 Further informations For further information please contact your dealer or company WDT Werner Dosiertechnik GmbH Co KG 1 5 Used symbols Danger Warning of Danger Failure to obs...

Page 3: ...y After any repair work have qualified personnel check the safe operation of the unit Use original spare parts only Additional national safety regulations also fully apply to the operation of this uni...

Page 4: ...After you press the push button the dosing is activated for 0 5 seconds till 5 seconds adjustable and aroma is injected into the steam pipe Afterwards the dosing is locked for an adjustable 1 20 minu...

Page 5: ...6 Fragrance pump A peristaltic dosing pump is used for dosing which safely promotes also smallest quantities Even when Air or gas bubbles are trapped in the suction line Rotating rolls press the dosi...

Page 6: ...t persitaltic pump frangrance The peristaltic pump article no Transparent pump cover Sa 14259 Safety disc for roller Sa blue 13633 Hose holder Sa for fragrance with Viton hose 13358 Hose set Sa 2 dosi...

Page 7: ...ommissioning Dosing The dosing unit has to be mounted in an easily accessible place on the wall about 1m above the floor The fragrance canister is placed under the unit The suction hose is inserted in...

Page 8: ...sensor head Then you adjust the desired dosing value at the rotary knob for the dosage The dosing pump delivers per second running time approximately 1 ml fragrance The green LED indicates the unit i...

Page 9: ...suring points is 730 ohms If the switch on temperature should be changed so you can do these when you turn the adjustment screw at the potentiometer If you turn clockwise the switch on temperature wil...