6
Operation / service
6.1
General
The tasks described here may only be carried out by appropriately trained and instructed personnel.
Alternatively, the work may be done by operating personnel who have read and understood the entire
operating instructions.
Once all preparations for the commissioning have been completed, the operation can be started. Turn on the
device at the mains switch (unless this has already been done).
CAUTION!
Risk of injury due to rotating peristaltic pump.
Operation with the protective cover
removed is prohibited.
6.2
Control unit - Software
The control unit is operated via the device’s control unit (display with 3 buttons).
The start push button is located on the button plate.
Overview control unit
Key
2. Peristaltic pump
3. Control housing with built-in compressor
4. Display
5. 3 buttons for operating the display
22. Ventilation grille
23. Mains switch
Operation of the control unit
The device is operated by means of 3 operating buttons next to the display.
Use the
arrow keys
to navigate up or down or to set numerical values.
Use the
Enter key
to acknowledge the selected submenu. The Enter key can also
be used to navigate back to the previous screen.
Figure 16, Control unit