Maintenance Protocol WP-075-EN
Foamdos V6
Z:\org-wdt\02 Qualitätsmanagement\ISO 9001\MS - Originale - Formuale, Prüfbericht etc\WDT Wartungsprotokolle WP\WDT-WP-075-EN-FOAMDOS-V6 FO 00.docx
Key: 1 = monthly, 3 = every 3 months, 6 = every 6 months, etc.;
= Work completed
Page 1 of 1
This protocol is to be completed by the maintenance technician! We reserve the right to determine the warranty
conditions when no completed and signed maintenance protocol is available.
Object: ........................................................................................... Maintenance year: 20___
City, street, house number: ............................................................................................................................................
Device type: ................................................. Year of manufacture: .................. Serial number: ..................................
Activity
M
ain
te
nance
in
te
rval
in
m
onths
M
onth 1
M
onth 2
M
onth 3
M
onth 4
M
onth 5
M
onth 6
M
onth 7
M
onth 8
M
onth 9
M
onth 10
M
onth
11
M
onth 12
Comment / additional tasks
1
Water supply part
1.1
Check device for leaks
3
1.2
Activate valves, check for function and leaks
3
2
Dosing technology
2.1
Check the peristaltic pump’s hose
1
2.2
Check entire dosing technology for leaks
3
2.3
Check compressor function; renew, if
necessary
6
2.4
Renew the peristaltic pump’s hose
12
2.5
Renew sealing rubber for the “Foam” dosing
valve
12
2.6
Renew sealing rubber for the “Flush” dosing
valve
12
3
Foam / Flushing withdrawal point
3.1
Visual check; clean / decalcify, if necessary
1
4
Control unit
4.1
Check electric cables for damage
12
5
Other Tasks
5.1
Clean the system
1
Additional remarks:
Maintenance carried out and device checked for function:
Date:
Signature
Countersigned by operator:
Signature