Dosing Device Foamdos V6
Index: 00
Date modified: 18/05/2021
OI No.: BA DW 025-00 Foamdos V6 EN.DOCX
Page 7 of 37
3
Product description - scope of delivery
3.1
Scope of delivery / accessories
Micro-processor control unit UNPL inside the control housing
Diaphragm air pump 7006 AC
Inlet with ball valve 1/2” JG and filter MS 1/2”
System separator in accordance with EN1717
Pressure reducer for regulating the system pressure
Needle valve for regulating the water flow during foam generation
2 solenoid valves 3/8” (for flushing and foam generation)
Foam generator for foam generation
Peristaltic pump SA
Suction lance d 12-420 mm
2 x dosing valve for foam concentrate and air
Hose PVC 12 x 1.5 transparent for foam dispenser
Button plate 2 x with 2 Piezo push buttons and flush-mounted box
Completely pre-assembled and pre-wired on mounting plate PP grey
Transition nipple for foam line from 3/8” to ½”
On-site services
Technical room/ cabinet for installation of the control panel; alternatively: Installation below the massage
table
Isolated ground socket; recommended: VDE B12 fuse
Thermostatic mixer / water connection mixed water 1/ 2”
Required pressure at the transfer point: min. 1.5 bar flow pressure
Water volume: approx. 10 l/min
Drain DN40 / gully in the technical room
Accessories/ options
Thermostatic mixer for the correct water temperature during the flushing function
Hand-held shower head for foam outlet
Shower head hose
Drain valve (solenoid valve)
3.2
Product description
The FOAMDOS dosing device produces a massage foam from the 3 components water, air and foam
concentrate, which is applied to the guest during hammam massages. The massage foam can also be used for
body care during the steam bath. A flushing function is integrated. The water flow and thus the consistency of
the applied foam can be individually adjusted on the device by means of a needle valve.
Foam generation and flushing can be switched on and off separately at the external button plate. After
switching off the flushing, the compressor continues to run for a preset time in order to blow empty the line
(optionally adjustable).
Settings in the programme can be made on the LCD display.