6.6
Adjust the foam consistency
The consistency of the massage foam is set via the water
volume. The setting is done at the needle valve (6).
Turn clockwise:
The water flow is decreased, the foam becomes firmer.
Turn counter-clockwise:
The water flow is increased, the foam becomes more liquid.
6.7
Replenish consumables
Replace the canister with foam concentrate
a)
Unscrew the lid of the new canister.
b)
Place the suction lance in the canister.
c)
Screw the suction lance’s lid on the canister.
d)
Check that the suction lance reaches the bottom of
the canister.
e)
If necessary, push suction lance downward.
f)
Vent foam line
After replacing the canister, the foam line may be
empty. Press the “
Foam
” push button on the button
plate until the foam runs out at the withdrawal point. The display shows
“Test foam”
.
Figure 18, Needle valve
6
Figure 19, Suction lance