GRANUDOS S5, control unit
Index: 02
Date modified: 11/05/2021
OI No.: BA SW 014-02 Granudos S5-Steuereinheit EN.docx
Page 15 of 29
Main menu
Settings
Config. Cl (chlorine dosing performance) (password entry)
This setting can only be executed by entering the password.
DS denotes dosing screw
Here, the dosing components: dosing motors, dosing screws that can be used are
displayed. The values are preset ex works and are used as the basis for determining the
defined maximum dosing performance that is shown when the display is switched on.
The maximum permanent dosing performance defined from the config. is shown here.
To change the desired dosing performance, the cycle time and the chlorine dosing time
(Menu Settings
Dosing performance) can be changed.
ATTENTION!
These values may only be changed if the appropriate components have been installed
in the dosing device. Otherwise, the dosing performance will be displayed incorrectly!
Maximum achievable dosing performance depending on the dosing motor’s rotation speed and the
diameter of the dosing screw.
Rotation speed of the dosing
motor
Diameter of the dosing screw
maximum dosing performance* -
default
12 rpm
19 mm
600 g/h
35 rpm
19 mm
1600 g/h
60 rpm
19 mm
2200 g/h
12 rpm
26 mm
1000 g/h
35 rpm
26 mm
3300 g/h
60 rpm
26 mm
4800 g/h
* The specified values are the maximum dosing performance of the GRANUDOS. This represents 50% of
the permanent dosing performance. These are approximate /- 20% - depending on the condition of
the granulate and dosing screw.
Main menu
Settings
Config pH (acid dosing performance) (password entry)
This Input can only be performed by entering the password.
The hose length of the
installed
peristaltic pump for acid is set here. The values are
preset ex works and are used as the basis for the dosing performance display.
If an
external acid pump
is used, the menu item "External" must be selected and the
external pump's dosing performance must be entered.
The maximum possible dosing performance is displayed here – see below. To change
the dosing performance, the cycle time and the pH dosing time can be changed (Menu
Settings
Dosing performance).
If the cycle time is changed, the chlorine dosing performance and the pH dosing
performance change
at an equal ratio
.
ATTENTION!
These configuration values may only be changed if the appropriate components have
been installed in the dosing device. Otherwise, the dosing performance will be
displayed incorrectly!
2400