Granudos 45/100-CPR Touch XL + Touch + S5
Dosing unit
Index: 02
Date modified: 06/06/2019
OI No.: BA SW 003-02 Granudos 45-100 CPR Touch+Touch+S5-Dosiereinheit EN.docx Page 35 of 58
4.
Unscrew the screw cap from the full acid canister, immediately insert the suction lance
into the canister and close it securely.
5.
Store the original screw cap of the acid canister until the next time the acid is replaced.
5.2.3
Attach/change the drum
PROTECTIVE CLOTHING!
Personal safety equipment must be put on before starting work with
chemicals: Tight-sealing goggles, protective gloves, apron, face
protection, boots
The safety data sheets for each chemical must be observed.
ATTENTION!
At the time of the order, the GRANUDOS 45/100 was manufactured
for a certain type of chlorine drum. As a rule, the dosing head does
not fit on chlorine drums by other manufacturers. If a dosing head is
improperly installed on a different drum, it may detach from the
drum during turning, causing the chlorine granulate to drop to the
ground. The removal of the chlorine is unpleasant and time-
consuming! This circumstance should be taken into account when
purchasing the chlorine.
The chlorine granulate and the acid must not be mixed with each
other or with other chemicals or substances!
Remove potential encrustations from the
dosing hopper (23)
to avoid
faults in the chlorine dosing.
The following can be checked upon delivery to gain an initial impression of the quality:
The granulate must be white, free of clumps, and no strong chlorine smell must be present
when opening the drum.
More detailed chlorine specification,
Tip!
It is recommended to roll the new, sealed drum several times on the
floor prior to attaching it to the dosing device to loosen any potential
clumps in the granulate.