background image

 

                                   operation manual SAUNA-VII (07/12)                 

page 11 of 14 

 

5.6

 

Checking the press switch 

  

Adjust the programme switch to T-pressure. The “splash indication” LED 

shines for five seconds with a delay of 2 seconds. Afterwards, the solenoid 

valve is switched on and water flows to the oven. The LED “splash” shines. 
After the lapse of the test programme, the LED “operation” blinks. The 

controller waits for a new adjustment. If a LED blinks during the checking 
procedure, the pressure switch is adjusted wrongly or it is defect. The test 

is stopped immediately.    

 

 

5.7 

Trouble shooting 

 
Fault: 

 

 

 

 

Solution: 

LED „splash report“ blinks:                 - turn the adjustment screw a half 

rotation to the right 

 

 

and repeat test 

 

 

- change the pressure switch 

LED „splash“ blinks:                   

 

 - water pressure too low, open 

valves and clean filter  
- turn the adjustment screw a half 

rotation to the left and repeat test 

  

- change the pressure switch 

 

 

  „no fragrance dosing – no aroma in the Steam Room?“ 

 

   

-

 

Fragrance canister empty?  

-

 

Does the pump run? 

 Test function (see above). 

-

 

Check the function of the pump: Pull the suction hose of the pump out 
of the fragrance canister – does a air bubble appear in the hose? Is it 

aspirated? If yes, the suction function of the pump works. 

 Is the roller of the pump rotating? Consider: If the water pressure is 
low the pressure switch locks the fragrance dosing. This is to ensure 

that fragrance oil is not dosed onto the oven without water.  

-

 

Check the pump hose on cracks, deformation.   

-

 

Check the roller of the pump on tracks of wear, springs broken, is the 

hose mounted correct?   

-

 

Check the dosing valve (blocked, clotted?) Remove the dosing tube 

from the valve by opening the cap nut of the hose connection (Pay 
attention that no fragrance splashes out as the hose is on pressure). 

Switch-on the pump. If fragrance is pressed out of the tube the pump 

works properly. Unscrew the dosing valve of the steam tube and make 
the same test. If no fragrance is pressed out of the dosing valve it is 

blocked. 

 

„no spalsh?“ 

 

-

 

Is the unit switched on? Does the „LED operation“ at the controller 
shine? Check the fuses! 

-

 

Is the splash sprinkler fossil? 

-

 

Check the supply pressure – if the pressure is too low the pressure 

switch will switch off the unit 

Summary of Contents for SAUNA-Plus VII

Page 1: ...tment of the dosing 5 3 The dosing pump 6 3 1 Changing the hose set 6 3 2 Dosing valve 7 3 3 Fragrance canister 7 4 Installation Taking the unit into operation 7 4 1 Installation 7 4 2 Electrical conn...

Page 2: ...ve 9 into the water that streams to the oven A a result it is ensured that the fragrance concentrate is only dosed when there s pressure in the water tubing Additionally the installed security combina...

Page 3: ...connections for PTFE hose 6x1 push button for external control clock timer 2 2 The controller 2 2 1 Cycle pause in minutes The cycle time time from splash to splash is adjustable from 10 to 60 minute...

Page 4: ...T pump test of the fragrance pump for 20 seconds afterwards the operation LED blinks the controller waits for a readjustment T valve test of the solenoid valve for 20 seconds afterwards the operation...

Page 5: ...the controller The lead time can be adjusted to 0 30 60 or 120 seconds see wiring diagramme 2 2 7 Adjustment of the dosing The cycle time time from splash to splash is adjusted by the left rotary knob...

Page 6: ...It is extraordinary safe in its function an in addition to this very easy to handle see mounting Fragrance concentrates are extremely aggressive The used dosing hose is resistant against the most con...

Page 7: ...e canister The SAUNA Plus VII is delivered to be mounted on the wall the fragrance canister volume 1 5 l is pre mounted at the mounting plate 4 Installation Taking the unit into operation 4 1 Installa...

Page 8: ...an also be pre installed ex works The connection for the water supply at the ball valve is for the splash tubing 3 8 The fragrance canister has to be filled and the suction tube has to be hung into it...

Page 9: ...fore the oven If a non return valve is installed a tube cutter is absolutely necessary Option For the assembly and safe fixing of the splash sprinkler we offer a grommet with two threads 3 8 made of s...

Page 10: ...hen there s a need to check it For this purpose release the dosing hose and screw out the dosing valve If you blow through the valve from the screw in side it has to be hermetically sealed If this is...

Page 11: ...bove Check the function of the pump Pull the suction hose of the pump out of the fragrance canister does a air bubble appear in the hose Is it aspirated If yes the suction function of the pump works I...

Page 12: ...operation manual SAUNA VII 07 12 page 12 of 14 Open all ball valves Clean filter central filter in technical room Test every single function component with the test switch 6 Wiring diagramme...

Page 13: ...rommet felt EPDM 12709 pump motor 13557 mounting screws 17067 hose holder with dosing hose 13358 dosing hose with hose clamp 12782 Control housing ABS with imprint 16878 knob for control board 11031 v...

Page 14: ...nce flexible pressure tubing PTFE 4x1 Identification Article no ball valve MS 10423 oblique sitting filter MS 11479 protection group 11465 solenoid valve Va 15072 solenoid valve connector 13082 dosing...

Reviews: