Brine Nebulization System, Type Soldos V3
Index: 03
Change date: 01/03/2017
Operating instructions no.: BA DW 005-03 Soldos V3 EN.docx
Page 51 of 70
6.6.1
Inputs test menu
This function can be used to test the 3 electrical inputs to the controller.
The test column shows the actual state for the respective input. Select the desired
test line and start it in the test column.
If the electrical input is open, than no electrical signal is provided to the input, a 0
is shown.
If the electrical input is closed, than an electrical signal is provided to the input, a
green 1 is shown.
Explanation:
Button: A signal from the button is provided (only when button operation is active).
External input: A signal from an external unit is pending. (e.g. from WDT central
controller)
Pressure switch: A signal is provided by the pressure switch. (only Soldos SL)
SL12 1/2: Number of clamp and number of the clamp strip on the control panel.
6.6.2
Outputs test menu
This function can be used to test the electrical outputs of the controller.
Select the desired test line and start it in the test column.