Brine fog maker, Type Solfog V2
Index: 01
Change date: 12/12/2017
Operating instructions no.: BA DW 018-01 Solfog V2 EN.docx
Page 30 of 39
Fault indications
The following fault messages may be shown. See the following fault table for removing the fault messages In case
of a failure at the device, the atomisation is interrupted.
Brine fog maker
Fault indication 1
Container empty
Fault indication 2
Filling time exceeded
Fault indication 3
Hose break
Fault indication 4
Push button cycle not active
Fault table
Fault indication / fault
Possible cause
Actions
Fault indication 1, Container empty;
Brine politainer empty
Hose pump not operating
Plug level control taken
off/defective
Change politainer
Check hose pump
Check plug level control
Fault indication 2, Filling time
exceeded;
Brine politainer empty
Hose pump not operating
Plug level control taken
off/defective
Change politainer
Check hose pump
Check plug level control
Fault indication 3, Hose break;
Pump hose defective
Check / exchange the pump hose
Fault indication 4, Push button cycle
not active
Wrong operation mode
selected
Select correct operation mode
The device cannot be switched on
Main fuse defective
Main switch defective
Power supply interrupted
Check / exchange the fuse
Check main switch
Check the power supply
Device without function
Wrong setting
Main fuse defective
Control board defective
Plug pulled off
Check / reset settings
Replace fuse
Check / exchange the board
Check the plug
Solenoid valve without function
Fuse defective
Solenoid valve / coil defective
Replace fuse
Check / exchange the solenoid valve
Hose pump without function
Fuse defective
Pump motor defective
Replace fuse
Check / exchange the pump motor
Button illumination does not work
Fuse defective
Replace fuse
No fragrance
Fragrance tank empty/dried
Fuse defective
Fan defective
Check / refill fragrance
Check / replace fuse
Replace dosing hose
No fog production
No brine fog
Check the conduct on leakages
Ultrasonic brine maker defective /
exchange
Check / exchange the fan
Check the plug of the ultrasonic fog
maker
The stored adjustments will get lost
Dip switch SW2-5 in position
ON