Brine Fogging System Type SOLFOG V3
Index: 02
Change date: 19/09/2023
OI No.: BA DW 042-02 Solfog V3 CB36 EN.docx
Page 27 of 65
7.7.2
Reactivating the device
7.8
Carry out disinfection with politainer change
7.8.1
General information regarding disinfection
CAUTION!
Health hazard due to lack of disinfection!
It is of particular importance to regularly carry out disinfection as a protection
against germs and bacteria. The Hypochlorous acid/hypochlorite required for
disinfection is generated by dissolving the enclosed disinfection tablet (Code
no. 19871).
Each disinfection must be documented in the disinfection protocol!
7 days downtime
In case of a downtime of up to 7 days, the device can be recommissioned without disinfec-
tion.
If the device has not been operated for more than 7 days, this must be documented in the
disinfection protocol, and a disinfection must be carried out at start of operation!
28 days operation
CAUTION!
Health hazard due to limited shelf life of the brine!
After opening, the brine politainer has a maximum shelf life of 28 days!
Dispose of the brine politainer with the residual content once this shelf life
has expired!
The brine politainer must be changed at least every 28 days and a disinfection must be car-
ried out.
On the 25th day, the display shows a message that a disinfection will be required in 3 days,
at the latest.
Fig. 17: Display with operation display
After reactivation, the device starts in the operation display
and is immediately ready for operation.
The display is illuminated.
The display shows the set times for:
the pause time,
the fogging time and
the cycle time (only for “Push button” operation
mode).
The current time is shown on the bottom row to the left.
When the timer is activated, the next switch time is shown
at the centre/right (e.g., Thu 5:00 p.m.).