Page 1: ...1 of 65 Operating Instructions Brine fogging system Type SOLFOG V3 WDT Werner Dosiertechnik GmbH Co KG Hettlinger Str 17 D 86637 Wertingen Geratshofen Germany Phone 49 82 72 9 86 97 0 Fax 49 82 72 9...
Page 2: ...entification plate on the device at hand Reproduction of any kind and translation into other languages even in excerpts is only permit ted with the express authorisation of the company WDT Werner Dosi...
Page 3: ...3 4 5 Button plate option 14 3 4 6 Lighting system for fog outlet option 15 3 5 Technical data 15 4 Transport and storage 16 4 1 General safety notices 16 4 2 Packaging 16 4 3 Temporary storage of the...
Page 4: ...ice information 45 8 7 15 Display data log 45 8 7 16 Conduct a reset 46 8 7 17 Config set password protection 46 8 7 18 Set Config Push button illumination 47 8 8 Change the brine solution 48 8 9 Repl...
Page 5: ...w werner dosiertechnik de Produkte Wellness Vernebelung von Soleloesung 1 2 Target group Only our authorised partners and people who have been trained in the device functions are permitted to work on...
Page 6: ...cautions for ESD sensitive devices must be ob served when handling the devices NOTICE A Notice denotes information that is of particular importance for the smooth running of op erations and that can d...
Page 7: ...livery subject to correct installation and commissioning with a completed and signed commissioning protocol Exempt from this are wear parts such as seals hoses diaphragms dosing screws electrodes roll...
Page 8: ...formation regarding support queries identification plate The control unit of the brine fog maker type SOLFOG V3 is subject to continued further devel opment of both its firmware and hardware We always...
Page 9: ...ation after decommissioning Commissioning Operation Maintenance servicing Disposal The attachment or installation of additional equipment is only permitted with the manufac turer s written approval Pa...
Page 10: ...power supply and se cure them against being reactivated Pay attention to the warning notices on the device After corresponding electrical installation or repair test all protective measures used e g e...
Page 11: ...ignition sources e g hot surfaces sparking open fire or cigarettes Carefully read and pay attention to the operating instructions prior to installation and use of the device In the event of malfunctio...
Page 12: ...number on the identification plate correspond to the details in the order ing and delivery documents and the equipment is complete and all parts are in perfect condition In the event of any transport...
Page 13: ...onnected cabin By default the device is started with the main switch Optionally the device can be controlled via a push button from the cabin or via an external signal Operation without brine If the S...
Page 14: ...ose the fragrance container Fig 1 No 15 must be filled up to the mark max 50 ml with a fragrance oil concentrate for room scenting and a filter star must be inserted The fan Fig 1 No 13 blows the evap...
Page 15: ...ed washer at the fog outlet into the cabin SOLFOG V3 Dimensions and weights External dimensions WxHxD 0 40 x 0 71 x 0 25 m Space requirement WxHxD 0 50 x 0 90 x 0 30 m Space requirement including op e...
Page 16: ...particular plastic bags out of reach of children NOTICE Please pay attention to the notices and pictograms attached to the carton 4 3 Temporary storage of the device ATTENTION Damage to the device due...
Page 17: ...ion site Installation is only permitted in the technical room Pay attention to the information regarding the installation site and the tech nical room in the technical data on page 14 The installation...
Page 18: ...At unsuitable walls e g porous or unstable or with inadequately dimensioned fas tening material e g screws that are too short or unsuitable dowels the device may detach from the wall Pay attention to...
Page 19: ...ystem Fig 8 Installation plan SOLFOG V3 without lighting system Installation with lighting system Fig 9 Installation plan SOLFOG V3 with lighting system Cabin wall Cabin Technical room Minimum gradien...
Page 20: ...n of larger germ concentrations Piping without fog lighting system To install the piping proceed as follows 1 Find a suitable location for the fog inlet into the cabin 2 Drill a 40 mm hole in the cabi...
Page 21: ...ter Maximum line length 4 m Connect the special bend with the vertical fog maker pipe and connect it to the SOLFOG s outlet pipe Pay attention to the gradient in the line 4 Push the lighting rod into...
Page 22: ...os 11 is provided on the mounting plate 2 Connect the SOLFOG to the power supply 110 230 V AC 50 60 Hz with the power plug 6 3 Additional connection options The following additional connection options...
Page 23: ...il concentrates only for room scenting with the SOLFOG Keep out of the reach of children Do not allow to come into contact with skin or eyes Wear chemical resistant protective gloves and goggles ATTEN...
Page 24: ...ey only reactivates the backlighting 7 5 Insert the roller carrier at the fragrance pump WARNING Risk of crushing Injury to fingers crushing possible Only conduct the work when the device has been swi...
Page 25: ...ulty operation Fig 13 Peristaltic pump 31 Transparent pump cover not shown 32 Safety disc 33 Hose bracket with dosing hose hose bracket kit 34 Roller carrier covered 35 Pump casing 41 Suction connecti...
Page 26: ...to the factory settings the language and the parameters for pause time fogging time and operation mode must first be entered The corresponding displays are shown in sequence After successful entry th...
Page 27: ...be documented in the disinfection protocol and a disinfection must be carried out at start of operation 28 days operation CAUTION Health hazard due to limited shelf life of the brine After opening the...
Page 28: ...een started can only be cancelled by switching it off at the main switch After that the message Disinfection necessary is displayed every time the device is switched on The display Disinfection necess...
Page 29: ...it directly into the drain Pay attention to the nationally applicable regulations for environmental and drinking water protection Fig 21 Menu Rinse fog maker container 3 Loosen the two cable couplings...
Page 30: ...ting plug in the politainer connection Fig 26 Push the politainer into the console 12 Turn the connected politainer upside down and push it into the console Ensure that the yellow flange ring rests in...
Page 31: ...c pump delivers the disinfection solution into the fog maker container until the required fill level is reached The disinfection solution is vaporised by the ultrasonic fog maker and blown through the...
Page 32: ...ntainer 19 Pull the Fog maker container Fig 13 No 19 forwards out of the bracket and remove it downwards 20 Empty the fog maker container rinse it with drinking water and then replace the empty fog ma...
Page 33: ...ld the empty brine politainer in your hand with the lid pointing upwards 3 Unscrew the politainer connection from the empty politainer 4 Take a new brine politainer 1 kg or 5 kg hold it with the lid p...
Page 34: ...r and allergic reactions Undiluted fragrance oil concentrates may cause irritation and allergic reactions Do not drink smoke or rub in Use fragrance oil concentrates only for room scenting with the SO...
Page 35: ...display 8 4 Switching on off NOTICE When the device is switched on for the first time after commissioning or after a reset it starts automatically with the start query see Chapter 7 7 1 on page 26 Th...
Page 36: ...rt the commissioning with a disinfection 8 5 Button plate function 8 6 Fog lighting function Fig 39 Button plate sample illustration Start the programme Fog generation After pressing the button the SO...
Page 37: ...y to the test menus output test input test These must be actively exited A start button option can be plugged into a socket on the control housing as desired Fig 41 Menu sequence Pressing any Key Fig...
Page 38: ...e display shows the opera tion display Depending on the operation mode the operation display shows the corresponding information In Figure 43 top Push button operation mode In Figure 43 bottom Exter n...
Page 39: ...an only be cancelled by switching off at the main switch Notice If the Disinfection menu is exited with Esc the display returns to the main menu Fig 45 Menu Pause time The pause time denotes the time...
Page 40: ...via the push button option in the cabin and operated for the set push button cycle time with the settings of the pause and fogging time 8 7 6 Set push button cycle Fig 49 Illustration push button cyc...
Page 41: ...h the Enter key 2 Use the arrow keys to select the speed in percent and save with the Enter key The display returns to the main menu Fig 51 Menu Test outputs You can test the different electrical outp...
Page 42: ...inputs entry in the main menu and confirm with the Enter key The inputs are marked with a red circle on the right side Filled circle Input active Empty circle Input inactive Depending on the connectio...
Page 43: ...y switches back to the selection of Time or Date 5 In the overview select the Esc entry to navigate to the main menu Fig 55 Menu Timer weekly overview The timer function can be switched on and off wit...
Page 44: ...ue 4 Once the last possible entry has been confirmed the display switches back to the selection of the week day Use Esc to navigate to the higher level Timer menu 5 Select the Timer entry menu and con...
Page 45: ...r key The display returns to the main menu Fig 59 Menu Info You can display the device information in this submenu 1 Select the Info entry in the main menu and confirm with the Enter key The display s...
Page 46: ...e Enter key 3 Select the Yes entry using the arrow keys and confirm the entry with the Enter key Fig 62 Menu Config Password The Config menu can be found at the very bottom of the main menu In the Con...
Page 47: ...the push button Ex works setting is button with the button setting the button illumination and the fog lighting are inverted see wiring diagram Dimming of the fog lighting is not provided Settings exa...
Page 48: ...anging the brine politainer please pay attention to Chapter 0 on page 33 8 9 Replenish fragrance oil concentrate WARNING Danger of irritation or and allergic reactions Undiluted fragrance oil concentr...
Page 49: ...f necessary or use a new fragrance container 3 Insert a clean filter star Fig 64 No 81 in the fragrance container Fill the desired fragrance concentrate into the fragrance container up to the fill lev...
Page 50: ...d e g earthing resistance ATTENTION Danger due to static charge This safety notice denotes electronic components that may be damaged by electro static discharges The generally accepted safety precauti...
Page 51: ...fe and storage time WARNING Health hazard due to germ contamination Over aged brine solution can lead to the formation of germs which can enter the ap plication room via the fogging and be inhaled the...
Page 52: ...amage e g cracks discolouration in due time and to replace the dosing hose The dosing hose must be replaced at least every 6 months Fig 66 Individual components of the peristaltic pump 9 3 1 Replace h...
Page 53: ...e visible in the front and centre see Fig 67 Fig 67 Hose bracket kit marking 1 Disassemble hose bracket kit see Chapter 7 5 on page 24 2 To replace the dosing hose Fig 67 No 43 at the hose bracket Fig...
Page 54: ...he device must be carried out by specialist personnel only All electrical installations and any work on the device s electrical components must be carried out by authorised electricians only Prior to...
Page 55: ...w politainer Check peristaltic pump Check level control plug Filling time has expired Brine politainer empty Peristaltic pump does not work Level control plug un plugged defective Renew politainer Che...
Page 56: ...ct setting on the push button illumination Renew fuse Check electrical connection Correct settings in the Config menu No discernible scent Fragrance container empty dried up Fuse defective Fan defecti...
Page 57: ...head with a soft cloth microfibre cloth Remove and dispose of the brine politainer Remove the brine pump s roller carriers to avoid any damage to the dosing hose see Chapter 7 5 on page 24 Prior to an...
Page 58: ...o the national and local laws ordinances and regulations re garding the disposal of mechanical and electronic components Pay attention to the following notices when disposing of the device Thoroughly...
Page 59: ...Brine Fogging System Type SOLFOG V3 Index 02 Change date 19 09 2023 OI No BA DW 042 02 Solfog V3 CB36 EN docx Page 59 of 65 11 Documents 11 1 Declaration of conformity...
Page 60: ...Brine Fogging System Type SOLFOG V3 Index 02 Change date 19 09 2023 OI No BA DW 042 02 Solfog V3 CB36 EN docx Page 60 of 65 11 2 Wiring diagrams...
Page 61: ...Brine Fogging System Type SOLFOG V3 Index 02 Change date 19 09 2023 OI No BA DW 042 02 Solfog V3 CB36 EN docx Page 61 of 65...
Page 62: ...64 11 4 Operation data sheet NOTICE During commissioning enter the operating parameters in the operation data sheet Menu Factory setting Setting range Step During commissioning Date Optimised during o...
Page 63: ...hazard due to germ contamination Over aged brine solution can lead to the formation of germs which can enter the ap plication room via the fogging and be inhaled there Carry out a disinfection every...
Page 64: ...Item Designation Code no WDT Peristaltic pump Cover for pump casing Sa transparent 14259 Safety disc for roller carrier Sa grey 13633 Hose bracket with hose SA 3 2x1 6 Ph 13260 Gear motor to peristal...
Page 65: ..._____________________________________________________ ____________________________________________________________________________ _____________________________________________________________________...
Page 66: ......
Page 67: ...2 Device and lines checked for leaks 1 3 Fog line with a maximum length of 4 m with gradient toward the brine fog maker 1 4 Roller carrier inserted according to OI Chapter 7 5 1 5 Disinfection carried...
Page 68: ......
Page 69: ...1 2 Clean fog maker diaphragm with a soft cloth 1 1 3 Grease O ring on top of the fog maker container 1 1 4 Check peristaltic pump for function and leaks 1 1 5 Check device for leaks and conduct a vis...
Page 70: ......
Page 71: ...recess to sink the sealing flange with a depth of 3mm Dimensions 1 fold HxW min 130x97mm 2 fold HxW min 163x97mm 3 fold HxW min 196x97mm 4 fold HxW min 229x97mm d Break out an orifice for the empty co...
Page 72: ...uilding foam in the wall approximately 20 mm protruding due to flush system Insert cable d Install the supplied construction protection cap in the flush mounted box e Plaster the brickwork so that the...