Surge Protection

This product features built-in surge protection circuitry in compliance with 
applicable standards.
For comprehensive protection of a luminaire installation against lightning 
and electrical surges, it is essential to cover mains supply and data input 
lines at the distribution board level, by using respective primary (Type 1) 
and secondary (Type 2) surge arrestors in compliance with EN61643-11/
IEC61643-1.

Warning

Ensure that all required surge protection measures are in place and
activated prior to luminaire installation. Also, disconnect luminaires
before operating high-power devices such as, for example, electrical
arc welders.

Do not open during installation

This product is factory-sealed. 
Refer to the instructions contained in this 
document for details.

WE-EF LIGHTING

Installation and Maintenance

Instructions 

Inground Luminaire

ETC330-FS

EVC330-FS

ETC340-FS

EVC340-FS

ETC330-FS CC

EVC330-FS CC

ETC340-FS CC

EVC340-FS CC

 

ETC330-FS TW

EVC330-FS TW

ETC340-FS TW

EVC340-FS TW

Summary of Contents for ETC330-FS

Page 1: ...EN61643 11 IEC61643 1 Warning Ensure that all required surge protection measures are in place and activated prior to luminaire installation Also disconnect luminaires before operating high power devic...

Page 2: ...0 FS TW EVC330 FS CC EVC340 FS EVC340 FS CC EVC340 FS TW ETC330 FS ETC330 FS TW ETC330 FS CC ETC340 FS ETC340 FS CC ETC340 FS TW Accessories DMX Wireless RF for ETC EVC330 FS CC 430 0018 RF for ETC EV...

Page 3: ...t failure due to abnormal circumstances or at end of life replacement must be carried RXW E D VXLWDEO TXDOL HG DQG WUDLQHG SURIHVVLRQDO Warning Do not open luminaire while mains supply is switched on...

Page 4: ...the original manufacturer then the warranty will no longer be valid and shall become the full responsibility of the modifying person organisation Claims based on defects attributable to improper inst...

Page 5: ...h gravel base Fig I b With fully concreted installation drainage piping must be provided Fig II 3 Test drainage ensure water drains within 30 mins Warning warranty void if luminaire installed without...

Page 6: ...owards the object to be illuminated wall tree column 7 Framing should be installed to prevent vegetation from growing over the lens 6 Replace blockout cover Z prior to luminaire installation to preven...

Page 7: ...ne c DMX refer to separate wiring instruction for DMX cable Please refer to instruction inside SJB packaging For wallwash illumination only Ensure the arrow indicated on the sticker is facing the illu...

Page 8: ...ion blockout B ensure there is no stress on seal able junction box J or electric cables 12 Loosen countersunk screws C do not turn out Insert mounting lever L between head of countersunk screws C and...

Page 9: ...8 15 Remove lever L and tighten countersunk screws C hand tight...

Page 10: ...www we ef com WE EF LIGHTING United States of America Tel 1 724 742 0030 Fax 1 724 742 0035 info usa we ef com TO9192W0422 WE EF 2022 Technical specifications are subject to change...

Reviews: