background image

2

Light Source
LED

Maintenance
Apart from cleaning the product’s exterior surfaces, no special maintenance work is required. 
Do not use high-pressure cleaners.

In case of component failure due to abnormal circumstances or at end of life, replacement must be carried 

RXWE\DVXLWDEO\TXDOLĥHGDQGWUDLQHGSURIHVVLRQDO

Warning: Do not open luminaire while mains supply is switched on.

Summary of Contents for FLC122 LED

Page 1: ...and secondary Type 2 surge arrestors in compliance with EN61643 11 IEC61643 1 Warning Ensure that all required surge protection measures are in place and activated prior to luminaire installation Also disconnect luminaires before operating high power devices such as for example electrical arc welders Do not open during installation This product is factory sealed Refer to the instructions contained...

Page 2: ...1 IP55 IK07 Class I ta 40 C Wall Luminaire Surface Mounted FLC122 FLC142 ...

Page 3: ...pecial maintenance work is required Do not use high pressure cleaners In case of component failure due to abnormal circumstances or at end of life replacement must be carried RXW E D VXLWDEO TXDOLĥHG DQG WUDLQHG SURIHVVLRQDO Warning Do not open luminaire while mains supply is switched on ...

Page 4: ...WDOOLQJ DQG FRQQHFWLQJ WKH OXPLQDLUH Notice I WKH OXPLQDLUH LV PRGLĥHG E DQ ERG RWKHU WKDQ WKH RULJLQDO PDQXIDFWXUHU WKHQ WKH ZDUUDQW ZLOO no longer be valid and shall become the full responsibility of the modifying person organisation Claims based on defects attributable to improper installation and or application and the consequences thereof are excluded The installation on site must comply with...

Page 5: ...rt nylon plugs F Warning Ensure not to damage any electrical cable water pipe or other items drilling holes 5HPRYH PRXQWLQJ ĦDQJH A by loosening screws B 3 Check that rating shown on luminaire label conforms with mains electrical supply example FLC122 LED 120 277V 60Hz 145 XXXX SOE XXXXXXX LED 3000K 12W item no XXX 12 17 IP55 ...

Page 6: ... plugs J by inserting and tightening screws D Attention Nylon plugs J must remain in position to provide sealing 7 Connect mains supply cable G leads to respective terminals in of LED Driver K a ON OFF L Phase N Neutral Earthing b 0 10 V L Phase N Neutral Earthing D D 0 10 V control line 8 Ensure that all surfaces are clean and dry 3RVLWLRQ OXPLQDLUH RYHU PRXQWLQJ ĦDQJH A Tighten screws B ...

Page 7: ...www we ef com WE EF LIGHTING United States of America Tel 1 724 742 0030 Fax 1 724 742 0035 info usa we ef com TO9205W0422 WE EF 2022 Technical specifications are subject to change ...

Reviews: