background image

07-1036 Metric CDR 

 

Owner's Manual and 
Guide to Operations

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

MODEL WT-25LC & WT-25LCI 

ROLL LABEL 

REWIND MACHINES 

 

910 Bolger Court, Fenton, MO  63026 (USA)  (636) 343-0806  (800) 325-9777 

IMPORTANT: Read all instructions before using. 

 

 

Summary of Contents for WT-25LC

Page 1: ...Metric CDR Owner s Manual and Guide to Operations MODEL WT 25LC WT 25LCI ROLL LABEL REWIND MACHINES 910 Bolger Court Fenton MO 63026 USA 636 343 0806 800 325 9777 IMPORTANT Read all instructions befor...

Page 2: ...tance Scanner Optional 6 Speed of Operation 6 Accuracy of Counting 6 Photoelectric Counting System Controls 7 Stop at Preset Bypass Preset Switch 7 Count Labels Count Length Switch 7 Dark Energize Lig...

Page 3: ...photosen sitive epilepsy READ ALL INSTRUCTIONS AND SAVE THEM FOR FUTURE REFERENCE PURPOSE GENERAL OVERVIEW WT 25LC and WT 25LCI series rewind machines are made for the purpose of rewinding rolls of na...

Page 4: ...power is on UNWIND TENSION CONTROL The unwind brake is a mechanical friction type consist ing of a brake band wrapped around a drum An ad justing knob on the front of the machine provides a means of t...

Page 5: ...on opposite to the direction in which the roll was turning normally clockwise NOTE An alternate method of loosening the roll on the rewind is to hold the roll tight against the top of the table and tu...

Page 6: ...TCH POSITION STOP BYPASS PRESET BYPASS REWIND DIRECTION SWITCH AS REQUIRED MAIN SPEED CONTROL MINIMUM IDLE SPEED CONTROL MID RANGE WEB PATH ILLUSTRATIONS Figure 1A Web Path for WT 25LC Models Figure 1...

Page 7: ...set the final count Preset B as normal and set Preset A to any number larger than Preset B NOTE All Rewind Machines are equipped with an electronic programmable counter This counter is quite sophisti...

Page 8: ...ignificant role in the speed with which labels can be accurately counted However the counter system is capable of accurately detecting and counting high con trast targets inch wide at maximum machine...

Page 9: ...witch in the COUNT DOWN posi tion causes the counter to subtract counts each time a label passes through the scanner In order to remind the operator that the switch is in the COUNT DOWN posi tion the...

Page 10: ...to unlock the scanner C Place a strip of label material into the slot of the scanner Align scanner in the center of the gap between the labels until the green led comes on D While observing the LED s...

Page 11: ...be made with discretion These set tings are located on the printed circuit board closest to the terminal blocks on the motor control The motor control is located inside the control cabinet MINIMUM SPE...

Page 12: ...n LoC for a few se conds You are now ready to reprogram the counter SETTING SCALE FACTORS 1 Press PRGM 2 When FACtor appears press ENTER 3 When dP F A appears press PRGM Then press ENTER 4 Set dP F A...

Reviews: