16
2.5.1.5 CAN OPERATION
The CAN protocol provides an encapsulated form of the existing datalink used
for remote operation. CAN port is shown in Figure 7. This port is not terminated
within the unit. The supported bit rate is 250k baud rate. Contact Customer
Service Department for additional information.
Figure 7. ROS RS-232 and CAN Bus Ports
2.5.1.6 ETHERNET FIBER OPERATIONS
The Ethernet fiber protocol provides an encapsulated form of the existing datalink
used for remote operation (see Figure 8). Contact Webasto’s Customer Service
Department for additional information.
Figure 8. Connected Ethernet Fiber
2.5.1.7 REMOTE EMERGENCY STOP (OPERATIONAL)
Within the 900 EX there is a provision to allow installation of an external switch
to control the emergency stop function of the system. To enable a system
provided with this option, an electrical connection must be made between Pins 1
and 4 of this interface (Figure 9). Opening this connection will induce a complete
power-down of the 900 EX.
Summary of Contents for 900EX
Page 1: ...Installation Operation and Maintenance Manual EV Test Systems 900 EX ...
Page 6: ...iv ...
Page 7: ...Chapter 1 Introduction ...
Page 11: ...Chapter 2 System Description ...
Page 25: ...Chapter 3 Installation ...
Page 29: ...Chapter 4 Operation ...
Page 48: ...42 ...
Page 49: ...Chapter 5 Maintenance ...
Page 53: ...Appendix A Glossary of Terms ...
Page 58: ...52 ...
Page 59: ...Appendix B DC I O Connector Assembly ...
Page 63: ...Appendix C 900 EX Remote Voltage Sense Operation ...
Page 66: ...60 ...
Page 67: ...Appendix D High Voltage Interlock Wiring ...
Page 69: ...Appendix E Index ...
Page 72: ...22855 03 04 ...